Owner`s manual
PureLink by Dtrovision
TABLE OF CONTENTS 55
System Configuration
PM series Matrix Router's communication setting can be configured using a front panel touch
screen LCD not needing an external PC or device. This section will demonstrate how to set
RS-232, LAN, and Product ID information.
1) RS232
There are four values those need to be set for serial communication; baud rate, data bits,
stop bits, and parity. Click and select each value using touch screen and push enter button to
save.
Factory default (recommended) settings for serial communication are:
Baud rate - 19200
Data bits - 8
Parity - none
Stop bits - 1
Flow control - none
and supported settings are:
Supported Baud Rate: 4800 Bps, 9600 Bps, 14400 Bps, 19200 Bps, 38400 Bps,
57600Bps, 76800 Bps, 115200 Bps
Supported Data bit: 5 bit, 6 bit, 7 bit, 8 bit
Supported Parity: Non, Even, Odd
Supported Stop bit: 1 bit, 2 bit
See pg. 46 for RS-232/422 cable termination