Full Product Manual
E-6
E-7
CLEANING (cont.)
ULTRASONIC DISK
1. Unplug unit.
2. Empty the tank by pouring all the water on the
left side (see arrow inside tank). Remove the
mist tube by rotating it counter clockwise.
3. Locate the ultrasonic disk on the
inside center of the base unit.
4. Use ONLY the enclosed cleaning brush
to gently clean disk and remove build up
and deposits.
Do not scrub or scrape the ultrasonic disk.
Ultrasonic Disk
Clean the disk with the brush only.
No other cleaning tool should
be used. BRUSH ONLY.
If scale becomes difficult to remove with brush:
1. Fill the tank with: mixture of 1 tap. white vinegar and 1 tap. water.
2. Let solution stand for 5 minutes.
3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.
4. Also check mist nozzle and mist tube in water tank. Clean as needed.
5. Rinse the tank thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
• Follow the Cleaning and Descaling instructions when the humidifier will be stored at
the end of the season.
• Dry the humidifier completely before storing. DO NOT store with water inside the
Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOT OR HOUSING
YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER
OR PERSONAL INJUR Y.
TROUBLE SHOOTING GUIDE
Water vapor and humidity
are not produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6)
PROBLEM
SOLUTION
Air blows but water vapor
is not produced.
Excessive W ater: Remove a certain amount of water from the tank.
Excessive W ater in mist tube. Remove water from tank and mist
chamber and try again.
Detergent residue and/or oil ingredients from cosmetics, eta may be in
tank; wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6) If you use hard water, replace with softer water.
Humidity level is low.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6)
The water in the unit is too cold: Replace with cool, but not cold water.
Damage on the ultrasonic disk: Contact Customer Service
The humidity has
a bad smell.
Poor maintenance or dirty water: Clean the product thoroughly,
and fill it with fresh water. (see pa. E-5)
White dust is forming on
nearby furniture.
Hard water may deposit a certain amount of dust. Dust in the air also
settles because of added humidity in the room. Use distilled water if
this becomes a nuisance.
Unit has stopped working.
No or low water. Unplug unit and refill tank.
Water is accumulating
outside of unit or area
surrounding unit.
Saturation of humidity. Lower mist control setting.
Unit not level and water is accumulating. Unplug and place on level
surface. Point spray away from objects. Raise unit on a water-resistant
level surface 2-3 feet off of floor.
Increased noise level.
Unit must be placed on a flat, level, hard surface.
Make sure it is NOT placed on a soft or absorbent surface.
Red light below power dial.
Indicates low water. Unplug and refill tank.
R
O
T
A
T
E
C
O
U
N
T
E
R
C
L
O
C
K
W
I
S
E
Looking down
at the inside of
empty tank.