Technical information

Deltabar M PMD55
Endress+Hauser 7
Input
Measured variable Differential pressure, from which flow (volume or mass current) and level (level, volume or mass) are derived.
Measuring range
Nominal
value
Measurement limit Smallest span
(factory calibration)
1
MWP
2
OPL
3
Min. operating
pressure
4
Version in the
Order Code
5
Feature 070
lower (LRL) upper (URL) on one side on both sides
[mbar (psi)] [mbar (psi)] [mbar (psi)] [mbar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [mbar
abs
(psi
abs
)]
10 (0.15) –10 (– 0.15) +10 (+ 0.15) 0.5 (0.0075)
1 (15)
6
1 (15)
1.5 (22.5)
0.1 (0.0015)
7B
30 (0.45) –30 (– 0.45) +30 (+ 0.45) 1.5 (0.0225) 7C
100 (1.5) –100 (– 1.5) +100 (+ 1.5) 5 (0.075)
70 (1050)
7
160 (2400)
8
70 (1050)
160 (2400)
105 (1575)
240 (3600)
0.1 (0.0015)
0.1 (0.0015)
7D
500 (7.5) –500 (– 7.5) +500 (+ 7.5) 25 (0.375) 7F
1000 (15) -1000 (– 15) +1000 (+ 15) 50 (0.75) 7G
3000 (45) –3000 (– 45) +3000 (+ 45) 150 (2.25) 7H
16000 (240) –16000 (– 240) +16000 (+ 240) 800 (12) 7L
40000 (600) –40000 (– 600) +40000 (+ 600) 2000 (30) 7M
1) Recommended Turn down: Max 100:1.
Factory calibration Turn down: Max 20:1, higher on request.
2) The MWP (maximum working pressure; MWP = PN) for the measuring device depends on the weakest element of the components selected with regard to
pressure, i.e. the process connection has to be taken into consideration in addition to the measuring cell. Also observe the pressure-temperature dependency.
For the appropriate standards and further information ä 26.
3) OPL: over pressure limit; depends on the lowest-rated element, with regard to pressure, of the selected components (ä 26).
4) The minimum operating pressure indicated in the table applies to silicone oil under reference operating conditions.
Minimum operating pressure at 85°C (185°F) for silicone oil: 10 mbar (0,15 psi) (abs)
5) See also chapter "Ordering information"
6) Version "2" in the Order Code - Feature 60
7) Version "6" in the Order Code - Feature 60
8) Version "7" in the Order Code - Feature 60