Technical information

Deltabar M PMD55
4 Endress+Hauser
Flow measurement Design and operation mode
P01-PMD55xxx-15-xx-xx-xx-001
Flow measurement with Deltabar M PMD55 and primary element, left: Orifice plate and right: Pitot tube
1Deltabar M PMD55
2 3-valve manifold
QFlow
p Differential pressure, p = p
1
– p
2
Your benefits
Choice between five flow modes of operation:
Volume flow
Norm volume flow (European norm conditions)
Standard volume flow (American standard conditions)
–Mass flow
–%
Choice of diverse flow units with automatic unit conversion.
Low flow cut off: when activated, this function suppresses small flows which can lead to large fluctuations
in the measured value.
Contains two totalizers as standard. One totalizer can be reset to zero.
The totalizing unit can be individually set for each totalizer. This allows independent daily and annual
quantity totalizing.
Note!
For more information about the Deltatop flow measurement system, see
TI00422P: Deltatop Differential Pressure Flow Measurement with Orifices
TI00425P: Deltatop Differential Pressure Flow Measurement with Pitot Tubes
QQ
p
1
p
1
p
2
p
2
Q~
Dp
Q~
Dp
+
+
1
2
1
2