Installation manual
Table Of Contents
- Table of Contents
- 1 System Outline
- 2 Activation Key Installation
- 3 Installation
- 3.1 Before Installation
- 3.2 Installation of the PBX
- 3.2.1 Unpacking
- 3.2.2 Names and Locations
- 3.2.3 Opening/Closing the Front Cover
- 3.2.4 Attaching Fan Guards
- 3.2.5 Installation of Basic System or 2-shelf System (Floor Standing)
- 3.2.6 Installation of 3- or 4-shelf System (Tower Type)
- 3.2.7 Installation of 4-shelf System (Side-by-side Type)
- 3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)
- 3.2.9 Installing/Replacing the Power Supply Unit
- 3.2.10 Frame Ground Connection
- 3.2.11 Installing/Removing the Optional Service Cards
- 3.2.12 Cable Handling
- 3.2.13 Types of Connectors
- 3.2.14 Attaching a Ferrite Core
- 3.2.15 Fastening Amphenol Connector
- 3.2.16 Surge Protector Installation
- 3.3 Information about the Main Processing Card
- 3.4 Information about the Virtual Cards
- 3.5 Information about the Optional Shelf Expansion Cards
- 3.6 Information about the Built-in Shelf Expansion Card
- 3.7 Information about the CO Line Cards
- 3.8 Information about the Extension Cards
- 3.8.1 CSIF4 Card (KX-TDA0143) and CSIF8 Card (KX-TDA0144)
- 3.8.2 DHLC8 Card (KX-TDA0170)
- 3.8.3 DLC8 Card (KX-TDA0171)
- 3.8.4 DLC16 Card (KX-TDA0172)
- 3.8.5 SLC8 Card (KX-TDA0173)
- 3.8.6 EXT-CID Card (KX-TDA0168)
- 3.8.7 CSLC16 Card (KX-TDA0177), ESLC16 Card (KX-TDA6174), EMSLC16 Card (KX-TDA6175), and ECSLC24 Card (KX-TDA6178)
- 3.8.8 IP-EXT16 Card (KX-TDA0470)
- 3.9 Information about the Other Cards
- 3.10 Connection of Extensions
- 3.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays
- 3.12 Connection of Peripherals
- 3.13 LAN Connection
- 3.14 Power Failure Connections
- 3.15 Starting the PBX
- 4 Guide for the Maintenance Console
- 5 Troubleshooting
- 6 Appendix
- Index

Note for KX-NT265 IP-PT users
The supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the version,
follow the procedure below:
"AP Version".
Select
"Maintenance".
Software version
is displayed.
While starting up
Select
"Version display".
To exit the programming mode
PROGRAM
SP-PHONE
SP-PHONE
SP-PHONE
HOLD HOLD HOLD HOLD
Power Supply Unit Selection for Each Shelf
The PBX needs a power supply unit (PSU) suitable for its configuration. For each shelf, calculate the load
figure from the type and number of items of equipment to be connected, and then determine the type of PSU
that will be required.
Note
Regardless of the total load figure, if a shelf contains an ECSLC24 card, the PSU-L must be installed.
Load Figure Calculation
Equipment Type
Load Figure
PT KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
KX-T7560/KX-T7565 DPT 1
Other DPT/Other DSS console 4
APT 4
IP-PT 0
SIP Extension 0
Extension Card
*1
DHLC8 8
SLC8 8
ESLC16/CSLC16/EMSLC16 16
ECSLC24 24
CS (1 unit) 4
High-density CS (1 unit) 8
IP-CS (1 unit) 0
VPS (1 port) 1
*1
Only the extension cards that can support SLTs count for the load figures.