Installation manual
Table Of Contents
- Table of Contents
- 1 System Outline
- 2 Activation Key Installation
- 3 Installation
- 3.1 Before Installation
- 3.2 Installation of the PBX
- 3.2.1 Unpacking
- 3.2.2 Names and Locations
- 3.2.3 Opening/Closing the Front Cover
- 3.2.4 Attaching Fan Guards
- 3.2.5 Installation of Basic System or 2-shelf System (Floor Standing)
- 3.2.6 Installation of 3- or 4-shelf System (Tower Type)
- 3.2.7 Installation of 4-shelf System (Side-by-side Type)
- 3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)
- 3.2.9 Installing/Replacing the Power Supply Unit
- 3.2.10 Frame Ground Connection
- 3.2.11 Installing/Removing the Optional Service Cards
- 3.2.12 Cable Handling
- 3.2.13 Types of Connectors
- 3.2.14 Attaching a Ferrite Core
- 3.2.15 Fastening Amphenol Connector
- 3.2.16 Surge Protector Installation
- 3.3 Information about the Main Processing Card
- 3.4 Information about the Virtual Cards
- 3.5 Information about the Optional Shelf Expansion Cards
- 3.6 Information about the Built-in Shelf Expansion Card
- 3.7 Information about the CO Line Cards
- 3.8 Information about the Extension Cards
- 3.8.1 CSIF4 Card (KX-TDA0143) and CSIF8 Card (KX-TDA0144)
- 3.8.2 DHLC8 Card (KX-TDA0170)
- 3.8.3 DLC8 Card (KX-TDA0171)
- 3.8.4 DLC16 Card (KX-TDA0172)
- 3.8.5 SLC8 Card (KX-TDA0173)
- 3.8.6 EXT-CID Card (KX-TDA0168)
- 3.8.7 CSLC16 Card (KX-TDA0177), ESLC16 Card (KX-TDA6174), EMSLC16 Card (KX-TDA6175), and ECSLC24 Card (KX-TDA6178)
- 3.8.8 IP-EXT16 Card (KX-TDA0470)
- 3.9 Information about the Other Cards
- 3.10 Connection of Extensions
- 3.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays
- 3.12 Connection of Peripherals
- 3.13 LAN Connection
- 3.14 Power Failure Connections
- 3.15 Starting the PBX
- 4 Guide for the Maintenance Console
- 5 Troubleshooting
- 6 Appendix
- Index

1.3.2 Characteristics
Terminal Equipment Loop Limit
• PT: KX-DT300/KX-T7600 series DPT: 90 W; all other DPTs/APTs:
40 W
• SLT: 600 W including set
• Doorphone: 20 W
• CS: 130 W; PT-interface CS: 65 W
Minimum Leakage Resistance
15 000 W minimum
Maximum Number of Extension
Instruments per Line
1. for PT or SLT
2. by Parallel or eXtra Device Port connection of an APT/DPT and
an SLT
3. by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage 75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Central Office Loop Limit
1600 W maximum
Hookswitch Flash Timing Range 24 ms to 2032 ms
Door Opener Current Limit 24 V DC/30 V AC, 1 A maximum
External Relay Current Limit 24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit Power to the external sensor is provided from the EIO4 card and must
be grounded through the EIO4 card. For the connection diagram, refer
to "3.9.3 EIO4 Card (KX-TDA0164)". The PBX detects input from the
sensor when the signal is under 100 W.
Paging Terminal Impedance
600 W
MOH (Music on Hold) Terminal
Impedance
10 000 W
Document Version 2009-12 Installation Manual 33
1.3.2 Characteristics