- 1 System Outline
- 2 Activation Key Installation
- 3 Installation
- 3.1 Before Installation
- 3.2 Installation of the PBX
- 3.2.1 Unpacking
- 3.2.2 Names and Locations
- 3.2.3 Opening/Closing the Front Cover
- 3.2.4 Attaching Fan Guards
- 3.2.5 Installation of Basic System or 2-shelf System (Floor Standing)
- 3.2.6 Installation of 3- or 4-shelf System (Tower Type)
- 3.2.7 Installation of 4-shelf System (Side-by-side Type)
- 3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)
- 3.2.9 Installing/Replacing the Power Supply Unit
- 3.2.10 Frame Ground Connection
- 3.2.11 Installing/Removing the Optional Service Cards
- 3.2.12 Cable Handling
- 3.2.13 Types of Connectors
- 3.2.14 Attaching a Ferrite Core
- 3.2.15 Fastening Amphenol Connector
- 3.2.16 Surge Protector Installation
- 3.3 Information about the Main Processing Card
- 3.4 Information about the Virtual Cards
- 3.5 Information about the Optional Shelf Expansion Cards
- 3.6 Information about the Built-in Shelf Expansion Card
- 3.7 Information about the CO Line Cards
- 3.8 Information about the Extension Cards
- 3.8.1 CSIF4 Card (KX-TDA0143) and CSIF8 Card (KX-TDA0144)
- 3.8.2 DHLC8 Card (KX-TDA0170)
- 3.8.3 DLC8 Card (KX-TDA0171)
- 3.8.4 DLC16 Card (KX-TDA0172)
- 3.8.5 SLC8 Card (KX-TDA0173)
- 3.8.6 EXT-CID Card (KX-TDA0168)
- 3.8.7 CSLC16 Card (KX-TDA0177), ESLC16 Card (KX-TDA6174), EMSLC16 Card (KX-TDA6175), and ECSLC24 Card (KX-TDA6178)
- 3.8.8 IP-EXT16 Card (KX-TDA0470)
- 3.9 Information about the Other Cards
- 3.10 Connection of Extensions
- 3.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays
- 3.12 Connection of Peripherals
- 3.13 LAN Connection
- 3.14 Power Failure Connections
- 3.15 Starting the PBX
- 4 Guide for the Maintenance Console
- 5 Troubleshooting
- 6 Appendix
- Index

1.3 Specifications
1.3.1 General Description
Control Bus Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus H.100 bus conformity (1024 time slots)
Switching Distributed Switching
Power Input PSU-M 100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A; 50
Hz/60 Hz
PSU-L 100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A;
50 Hz/60 Hz
Maximum Power Failure Tolerance
*1
300 ms
Power
Consumption (per
shelf)
With PSU-M 190 W; 2.5 A (at 120 V AC; 60 Hz)
With PSU-L 410 W; 5.1 A (at 120 V AC; 60 Hz)
Memory Backup Duration 7 years
Dialing CO Line Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Mode Conversion DP-DTMF, DTMF-DP
Ring Frequency 20 Hz/25 Hz (selectable)
Central Office Loop Limit
1600 W maximum
Operating
Environment
Temperature 0 °C to 40 °C (32 °F to 104 °F)
Humidity 10 % to 90 % (non-condensing)
Conference Call CO Line (per shelf)
From 10 ´ 3-party conference call to 4 ´ 8-party conference call
Music on Hold (MOH) 2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging Internal Level Control: -15 dB to +6 dB in 3 dB steps
External 2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface
Port
RS-232C 1 (maximum 115.2 kbps)
RJ45 Port MNT Port 1 (for PC connection)
LAN Port 1 (for LAN connection)
Extension Connection Cable SLT 1-pair wire (T, R)
DPT 1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
APT 2-pair wire (T, R, D1, D2)
Document Version 2009-12 Installation Manual 31