Installation manual

Table Of Contents
PROBLEM PROBABLE CAUSE SOLUTION
During a power failure,
extensions connected
to ports 1 to 4 of
EMSLC16/ESLC16/
ECSLC24/CSLC16 and
ports 1 to 2 of DHLC8/
SLC8 cards do not
operate.
A DPT or APT is
connected to the
extension port.
The dialing mode (tone
or pulse) is incorrect.
Disconnect the DPT or APT and connect
an SLT.
Set the Tone/Pulse switch to the other
position.
Originating an outside
call, call transfer, or
conference cannot be
performed.
The corresponding
flexible button does not
exist on the PT.
Program the flexible button. Refer to
"6.1.3 Flexible Buttons" in the Feature
Manual.
The KX-HGT100 does
not work properly, or
some features cannot
be performed using the
KX-HGT100.
The firmware of the
KX-HGT100 and the
MPR software file
version of the PBX are
not upgraded to their
latest versions.
Upgrade the firmware of the KX-HGT100
and the MPR software file version of the
PBX to their latest versions.
Document Version 2009-12 Installation Manual 217
5.1.3 Operation