Installation manual
Table Of Contents
- Table of Contents
- 1 System Outline
- 2 Activation Key Installation
- 3 Installation
- 3.1 Before Installation
- 3.2 Installation of the PBX
- 3.2.1 Unpacking
- 3.2.2 Names and Locations
- 3.2.3 Opening/Closing the Front Cover
- 3.2.4 Attaching Fan Guards
- 3.2.5 Installation of Basic System or 2-shelf System (Floor Standing)
- 3.2.6 Installation of 3- or 4-shelf System (Tower Type)
- 3.2.7 Installation of 4-shelf System (Side-by-side Type)
- 3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)
- 3.2.9 Installing/Replacing the Power Supply Unit
- 3.2.10 Frame Ground Connection
- 3.2.11 Installing/Removing the Optional Service Cards
- 3.2.12 Cable Handling
- 3.2.13 Types of Connectors
- 3.2.14 Attaching a Ferrite Core
- 3.2.15 Fastening Amphenol Connector
- 3.2.16 Surge Protector Installation
- 3.3 Information about the Main Processing Card
- 3.4 Information about the Virtual Cards
- 3.5 Information about the Optional Shelf Expansion Cards
- 3.6 Information about the Built-in Shelf Expansion Card
- 3.7 Information about the CO Line Cards
- 3.8 Information about the Extension Cards
- 3.8.1 CSIF4 Card (KX-TDA0143) and CSIF8 Card (KX-TDA0144)
- 3.8.2 DHLC8 Card (KX-TDA0170)
- 3.8.3 DLC8 Card (KX-TDA0171)
- 3.8.4 DLC16 Card (KX-TDA0172)
- 3.8.5 SLC8 Card (KX-TDA0173)
- 3.8.6 EXT-CID Card (KX-TDA0168)
- 3.8.7 CSLC16 Card (KX-TDA0177), ESLC16 Card (KX-TDA6174), EMSLC16 Card (KX-TDA6175), and ECSLC24 Card (KX-TDA6178)
- 3.8.8 IP-EXT16 Card (KX-TDA0470)
- 3.9 Information about the Other Cards
- 3.10 Connection of Extensions
- 3.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays
- 3.12 Connection of Peripherals
- 3.13 LAN Connection
- 3.14 Power Failure Connections
- 3.15 Starting the PBX
- 4 Guide for the Maintenance Console
- 5 Troubleshooting
- 6 Appendix
- Index

System Initialization Procedure
1. Slide the System Initialize Switch to the "SYSTEM INITIALIZE" position.
System Initialize Switch
Reset Button
SYSTEM
INITIALIZE
RESET
NORMAL
RUN Indicator
2. Plug the AC power cord into the PBX and an AC outlet, and turn on the PBX. The RUN indicator will flash.
Note
For safety reasons, do not stretch, bend, or pinch the AC power cord.
To AC Outlet
3. While the RUN indicator is flashing, slide the System Initialize Switch back to the "NORMAL" position.
Depending on the configuration, initialization takes about 1 min to 3 min. If successfully executed, the
RUN indicator will stop flashing and stay lit.
All data will be cleared, and the PBX as well as all optional service cards (except for the IP-GW card) will be
initialized to the default values. The DPTs should show the time as 01:00.
The data of the IP-GW card will not be initialized.
Note
When initializing the PBX, the built-in ESVM card will also be initialized. Therefore, the built-in ESVM card
feature may not be used for up to 2 minutes after the PBX starts.
198 Installation Manual Document Version 2009-12
3.15.1 Starting the PBX