User manual

Step 5
Connect LC optical fiber between the transmitter and the receiver as shown in
figure 4.
Figure 4 Connection of optical fibers
Note: Both of single-mode and multi-mode fiber are applicable to OLC II up to
500meters. In the case of longer than 500meters, you have to use single-mode
fibers.
Step 6
Plug the transmitter to the DVI receptacle of the DVI source such as PC.
Figure 5 Connection of the transmitter to the DVI source
Note: Be recommended NOT to use any intermediate cable or adapter between
them to avoid undesirable performance degradation.
Step 7
Plug the receiver to the DVI receptacle of the display.
Figure 6 Connection of the transmitter to the display
Step 8
Make the PC and the display power ON.
Note: You can replace any DVI cable into an OLC II by following the Step1 to 7,
while all powers of PC and display are ON.
1-4 Installation
Self-EDID Programming Procedure
The graphic source equipment generally requires communication of display information
(EDID). Display information (EDID) contains resolution and timing information for your
display.
OLC II supports Self-EDID programming. Self-EDID programming means that the
EDID from the display is stored in the transmitter. You should use Self-EDID
programming feature if the resolution of the display is not UXGA(1600x1200). Follow
these steps to record the EDID of the display into the transmitter unit.
Note1 : If you know that EDID is not required by the source, Self-EDID
programming is not necessary.
Note2 : The factory default EDID setting is programmed in the VESA standard of
UXGA (1600x1200) 60Hz.
Step 1
Power on the display.
Step 2
Apply the 5V DC power adapter to the transmitter.
Step 3
Push the EDID PRGM. button of the transmitter with a pointy pin. Hold down
the button for 3 sec and release it.
Self-EDID LED EDID-PRGM. button
Figure 7 Position of EDID-PRGM. button and Self-EDID LED
Step 4
Connect the transmitter to the display while turned on, not to the PC. The
LED on the transmitter will begin to blink once. Blinking indicates reading the
EDID.
Step 5
Disconnect the transmitter from the display.
1-5 Self-EDID Programming Procedure