User manual
5
Environmental and Reliability Specifications
Recommended environmental conditions for the operation are temperature range of 10°C~40°C, non-
condensing humidity levels of 10%-80%, and altitude ceiling of 3,000 meters (9,840 feet).
Environmental limits for transportation are temperature range of -25°C ~ 60°C, non-condensing
humidity levels of 5%~95%, and altitude ceiling of 15,000 meters (49,200feet)
Environmental limits for storage are established at temperature range of -20°C~45°C, non-
condensing humidity levels of 5%~95%, and altitude ceiling of 3,000 meters (9,840 feet)
The DVI Pure Fiber Optic Extender Dual Link is expected to function for more than 50,000 hours of
use at a 90% confidence level. The device is tested according to the identical standards for testing
LCD monitors.