Instructions / Assembly
- 4 -
INSTALLATION
DC power.
Remove the Pre-Charge Kit from the positive (RED) battery lead ring. Open the Pre-
Charge Kit and wrap one of the resistor wires around the positive (RED) battery lead
ring.
3. Using the end not connected to the resistor wire, connect the positive (RED) battery
lead to the positive (RED) terminal on the Backup Power System. Secure the included
securely by hand. Do not use any tools to tighten as this may break the retention knob.
Connect the negative (BLACK) battery lead to the negative (BLACK) terminal on
terminal. Tighten the terminal retention knob securely by hand. Do not use any tools to
tighten as this may break the retention knob.
Connect the negative (BLACK) battery lead to the negative (BLACK) terminal on the
recommendation.
Touch and hold the free end of the resistor wire to the positive (Red) terminal on the
battery for 3 seconds. Completely remove the resistor wire from the positive (RED)
battery lead ring.
7. Connect the positive (RED) battery lead to the positive (RED) terminal on the
recommendation.
8.
9.
Flip the power switch into the ON position.
Allow the Backup Power System to charge the battery until the “Full” status indicator
LED is BLUE.
Test the AC power functionality by manually activating the connected sump pump(s).
Test the DC power functionality by unplugging the Backup Power System from the
sump pump(s).
ATTENTION
(Optional)
A Grounding Wire (yellow/green) is included to connect the Primary Sump Pump
Backup Power System’s Ground Connection to a grounded wall. Connect one end of
the Grounding Wire to the Ground Connection located below the USB Output. Connect
the other end of the Grounding Wire to the mounting hardware that is connected to a
grounded material. Additional hardware may be required.