Instruction Manual

Polymaster
Remote Models Selection Chart
Model
Number
Max Water
Flow
A Polymer
Inlet
B Dilution
Water Inlet
C Mixed
Solution Outlet
PAD-1200R
4,543 lph
(1,200 gph)
1
/
" FNPT 1" FNPT 1
1
/
" FNPT
PAD-3000R*
11,356 lph
(3,000 gph)
1
/
" FNPT 1
1
/
" FNPT 2" FNPT
Model
Number
Max Water
Flow
A Polymer
Inlet
B Dilution
Water Inlet
C Mixed
Solution Outlet
PMD-1200R
4,543 lph
(1,200 gph)
1
/
" FNPT 1" FNPT 1
1
/
" FNPT
PMD-3000R*
11,356 lph
(3,000 gph)
1
/
" FNPT 1
1
/
" FNPT 2" FNPT
Model Number Capacity Max. Pressure
532-VS-N3A 42 lph (11 gph) 6.9 bar (100 psi)
535-VS-N3A 68 lph (18 gph) 6.9 bar (100 psi)
547-VS-N3A 114 lph (30 gph) 6.9 bar (100 psi)
Model Number Capacity Max. Pressure
532-VS-N3M 42 lph (11 gph) 6.9 bar (100 psi)
535-VS-N3M 68 lph (18 gph) 6.9 bar (100 psi)
547-VS-N3M 114 lph (30 gph) 6.9 bar (100 psi)
Remote Pump
Automatic Units
The following models may be
specified with any automatic
electronic metering pump
(see chart on opposite page)
or with any motor-operated
metering pump from the automatic pump selection chart below.
These models may also be used with progressing cavity type pumps.
4-20 mA Pump Control Manual Pump Control
Motor-Driven Metering Pumps
For Use With Remote Automatic Polymasters
Manual Stroke Length Control • Automatic 4-20 mA Speed Control
Progressing Cavity Pumps May Be Used With Remote Automatic or Manual Polymasters
Advise type and size of existing pump and drive or specify requirements for new pump and drive.
Motor Driven Metering Pumps
For Use With Remote Manual Polymasters
Manual Stroke Length Control • Constant Speed Motor
*Motor-Speed Control for Remote Pump Units
All Remote Models Models PAD/PMD-1200R Models PAD/PMD-3000R All Models
9 8
7
3
1
1
10 2
10 10
5
11
A
2
5
1
6
4
46
11
C
B
55 cm
(21-5/8")
39 cm
(15-1/2")
56 cm
(22")
81 cm
(32")
9 cm
(3-5/8")
12 cm
(4-3/4")
12 cm
(4-3/4")
45 cm
(17-3/4")
* Post Dilution Model provides 4,543 lph (1,200 gph) initial dilution, 6,814 lph (1,800 gph) post dilution, independent water control valve and flow rate indicator for each dilution stage.
Remote Pump
Manual Units
The following models may
be specified with any manual
electronic metering pump
(see chart on opposite page)
or with any motor operated
metering pump from the manual pump selection chart below. These
models may also be used with progressing cavity-type pumps.
Post Dilution Model PAD/PMD-3000R
5