Specifications

Maintenance
Version 2011v1 35
3.6.2 Replacing the side frame
See fig. 020707030.
The side frame should be replaced as follows:
Support the wheelchair under the battery tray in such a
way that both drive wheels remain on the ground.
Remove swivel castor, see 'replacing swivel castor'.
Remove the drive unit; see 'replacing drive unit'.
Cut through the cable-wrapping tape for the cable and
the lighting.
Loosen bolts (A) using a spanner with a key width of
7 mm.
Remove the lighting unit (B).
Loosen the bolt (C) using an Allen key with a key width of
5 mm and stop the nut (D) using a spanner with a key
width of 13 mm.
Watch the bearing bushes (E) and the washers that come
loose at the same time.
Loosen the bolts (F) using an Allen key with a key width
of 6 mm.
Remove the side frame (G).
Loosen bolts (H and I) using an Allen key with a key width of 5 mm, in order to be able to remove the transport
locking system (J).
A (new) side frame should be placed as follows.
Apply a layer of grease to the hinge pin (K) and the bearing bushes.
Slide the side frame with the washers and the bearing bushes onto the hinge pin.
Follow the assembly with the placement of the drive unit; see 'replacing drive unit'.
Install the lighting and fasten the lighting cable to the side frame using a new cable-wrapping tape.
Mount the swivel castor, see 'mounting swivel castor'.
EBAPUM-020707030-nl.doc
3.6.3 Replacing carbon brushes
See fig. 020707040.
The carbon brushes of the drive units should be replaced as
follows:
Remove the drive unit; see 'replacing drive unit'.
Slide the rubber cover (A) to the back onto the drive
unit.
Slide the cover (B) of the carbon brush holder
backward.
This way, the carbon brush (C) becomes accessible
and can be taken out.
Inspect the carbon brush and replace it if necessary.
Also check the collector on the rotor of the motor
through the open carbon brush holder.
In case of serious wear of the collector
the drive unit must be entirely
replaced.
Do NOT make repairs on the drive unit,
because this will make the guarantee null and void.
Mount the carbon brush into the holder. This can be done in one way only!
Mount the sliding cover onto the carbon-brush holder.
Replace the drive unit; see 'replacing drive unit'.
Make sure that the sliding plugs of the connecting wires, on the drive unit, are properly connected.
A E B E C G
D K F I J H
020707030
B
C
A
020707040