SDS
Last Updated: July 25, 2019 Page 4/7
8. Exposure Controls/Personal Protection
Control Parameters
Components with limited values that require monitoring at the workplace: Not
required.
Exposure controls
Personal Protective Equipment
Pictograms:
Respiratory: In case of insufficient ventilation, wear suitable respiratory equipment.
Follow the OSHA respirator regulations found in 26 CFR 1910.134. Use a
NIOSH/MSHA approved respirator if exposure limits are exceeded or symptoms are
experienced.
Eye/Face: Wear safety goggles
Hands: Wear protective gloves
Skin/Body: Where extensive dermal exposure may be expected, either a chemical suit
or a chemical apron will be needed.
General Industrial Hygiene Considerations: Handle in accordance with good
industrial hygiene and safety practice. Wash thoroughly with soap and water after
handling and before eating, or drinking. Safety shower and eye wash should be
available close to work areas.
Environmental Exposure Controls: Follow best practice for site management and
disposal of waste. Avoid release to the environment.
9. Physical and Chemical Properties
Appearance: Clear, colorless liquid
Odor: Odour of soap and ammonia
pH: 7.85 ± 0.10
Boiling Point: Not determined
Melting Point: Not determined
Flash Point: >200˚C
Flammability: Product is not flammable
Decomposition Temperature: Not determined
Heat of Decomposition: Not determined
Danger of Explosion: Product does not present an explosion hazard