User manual
7.3.3. Table Structure and Parameter Ranges
xxx1 xxx2 xxx3 xxx4 xxx5 xxx6 xxx7 xxx8 xxx9 xxx0
Par.
No.
Begin of
number
Call
enable
call
routing
Number
length
End
#
End
*
Initial
tariff
Impulses
per [ms]
Take
away
Append
501
Max. 16
digits
0...9, *, #
0 = no
1 = yes
0=GSM
1=PST N
0,3...16
0 = no
1 = yes
0 = no
1 = yes
0...
...255
0 or
100 to
999900
0 – 16
Max. 16
digits
0...9, *, #
...
...
...
...
...
...
...
...
...
...
...
598 -//- -//- -//- -//- -//- -//- -//- -//- -//- -//-
A01 -//- -//- -//- -//- -//- -//- -//- -//- -//- -//-
...
...
...
...
...
...
...
...
...
...
...
A98 -//- -//- -//- -//- -//- -//- -//- -//- -//- -//-
B01 -//- -//- -//- -//- -//- -//- -//- -//- -//- -//-
...
...
...
...
...
...
...
...
...
...
...
B54 -//- -//- -//- -//- -//- -//- -//- -//- -//- -//-
599 Other
-//- -//- -//- -//- -//- -//- -//- -//- -//-
NOTE: Records A01 to A98 and B01 to B54 are programmable only by PC.
Values after Initialisation:
xxx1 xxx2 xxx3 xxx4 xxx5 xxx6 xxx7 xxx8 xxx9 xxx0
Par.
No.
Begin of
number
Call
enable
call
routing
Number
length
End
#
End
*
Initial
tariff
Impulses
per [ms]
Take
away
Append
501
to
530
Empty 1 = yes 0=GSM 0 1 = yes 0 = no 0 0 0 Empty
The table also includes a special line (500), where setting a few parameters can disable the
whole table or some columns. It is a quick way to the „emergency operation“ if there is an error
in the table and you have no time to locate it.
Line 500 – Table Blocking Parameters
Par. No. 5001 5002 5003 5004 5005 5006 5007 5008 5009
Meaning
Genera
l enable
Call
enable
General
routing
Number
length
End
#
End
*
Initial
tariff
Impulses
per [ms]
Take off
and
append
Value
range
0 = no
1 = use
table
0 = no
1 = use
table
2 = all
0 = GSM
1 = use
table
2 = PSTN
0 = no
1 = use
table
0 = no
1 = use
table
2 = yes
0 = no
1 = use
table
2 = yes
0 = no
1 = use
table
0 = no
1 = use
table
0 = no
1 = use
table
Default
value
1 1 1 1 1 1 1 1 1
General enable: if you disable the whole table with a zero, all numbers will be governed by line
599 – „Others“.