Option “4” Display IPMI EEPROM Information
This command displays the contents of the IPMI FRU EEPROM which holds the Part number and serial
number information as well as the full IPMI FRU header. Note: Although IPMI is not implemented in all
versions the IPMI EEPROM is always present.
Option “F” Force Software Reset
This command resets the PSOC device and restarts the firmware. As a result power will be toggled off then
on, effectively resetting the PMC and PLX controller. Re-initialization of the PXL and PMC may be
needed to continue operation. To prevent accidental execution the user is prompted to confirm this
command should be run.
Option “L” Load New Firmware via UART (Com Port)
This command updates the PSOC firmware over the serial interface. To prevent accidental execution the
user is prompted to confirm this command should be run.
Option “O” Force Secondary Power Off
This command turns off the 3.3V and 5V power to the PMC and the power to the PLX Bridge chip. The
+12V and -12V power is still supplied to the PMC. There is no command to turn power on. To prevent
accidental execution the user is prompted to confirm this command should be run.
Option “N” Resume Normal Fan Operation
This command returns the fan to normal operation after the fan override commands were executed. The fan
control algorithm will resume operation.
Option “–“ Override Fan – Decrease RPM
This command decreases the fan PWM by 10%, reducing the fan speed. This overrides the normal fan
operation and the fan control algorithm will not execute until command “N” is run.