19.3 Test Procedures
• Adjust DC offset of the signal generator/audio amplifier to 13.5 volts with the DUT disconnected (open circuit).
• Prior to testing, measure and verify that the test waveforms A, B, C, D and E match those waveforms illustrated in
section 19.2. For waveform F, measure and verify that the test waveform voltages are similar to that illustrated in
Figure 19-6 and 19-7. All measurements shall be made with the DUT disconnected from the waveform generator.
• Connect and activate the DUT. Verify that it is functioning correctly.
• Except for waveform E, apply each waveform into each power supply and control circuit separately. Apply waveform
E simultaneously to all power circuits with direct battery connections.
• Application of the waveforms shall be in accordance with the requirements delineated in Table 19-1. Monitor DUT
functions before and after application of each test waveform.
• Repeat testing for all DUT operating modes listed in the test.