Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 68 of 121
February 11, 2010
Figure 18-2: CI 250 Transient Pulse Detail
exp(-πft/10)sin(2πft)
1/f
U
S
2/f 3/f 10/f
0
-U
S
F(Hz) = 100x10
3
(100 kHz) U
S
= 5 volts
( peak to peak voltage = 2U
S
)
Figure 18-3: CI 250 Transient Pulse Delay Detail
d
n
Figure 18-4: CI 250 Requirements (Transient Disturbance Sequence)
See Pulse Detail
d1 d2 d3 d4 d5
d20
...
...
0
U
S
-U
S
.