14.0 Coupled Immunity: RI 150
These requirements are related to component immunity from wire-to-wire coupling of unintended continuous disturbances.
These disturbances originate from high current PWM sources and the vehicle’s charging and ignition system. These
requirements are applicable to the following component categories:
Electronic Modules: A, AS, AM, AX, AY
Electric Motors: EM
14.1 Requirements
The device shall operate without deviation (Status I) when exposed to sinusoidal electromagnetic disturbances delineated in
Figure 14-1.
Figure 14-1: RI 150 Coupled Immunity Requirements
0
1
2
3
4
5
6
7
1 10 100
kHz
I
P-P
(ampers)
Frequency (kHz) Stress Level ( I
P-P
)
1 – 10 6
10 – 100
10
log4.56
f
*
* f = frequency in kHz