Specifications
EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 30 of 121
February 11, 2010
g) If the DUT is of component categories AX, AY and EM, measure and record the peak transient voltages while
exercising the DUT functions in operating modes identified in the EMC test plan. This step may be omitted for
component categories BM and R.
h) For all component categories with switched power circuits, measure and record peak positive transient voltages
exceeding the trigger level while by turning the DUT off and on ten times (10 measurements for each condition) via
the external switch shown in Figure 10-1.
i) Repeat step e) through h) for each of the following time base values:
• 100 usec/div;
• 1 usec/div
• 0.5 usec/div
Alternative time base values may be selected if those listed are not available for the oscilloscope used. The lab shall
use the closest time base value available. The time bases used shall be documented in the EMC test report.
j) Re-adjust the trigger level of the digital sampling scope to -60 volts. Repeat steps e) through i) except record the peak
negative transient voltages exceeding the trigger level.
Design Note
Although CI 410 requirements are validated at room temperature, the product should be designed to meet the
same requirements at -45 degrees C or the coldest ambient temperature specified in the product's engineering
specification
Figure 10-1: CE 410 Transient Emissions Test
9
200 +/- 50
3
1
+
-
100 +/- 25
2
All Dimensions in mm
4
5
7
6
8
9
200 +/- 50
3
1
+
-
100 +/- 25100 +/- 25
2
All Dimensions in mm
4
5
7
6
8
Key:
1. Power Supply
2. Artificial Network (AN)
3. Mechanical /Electromechanical Switch
4. Digitizing Oscilloscope
5. High Impedance Probe (1:100, C < 4pf.
See ISO 7637-2) Example: Agilent 10076A
6. DUT
7. Insulated support (ε
r
≤ 1.4)
8. Load Simulator
9. Ground Plane