9.0 Conducted Emissions: CE 421
These requirements are applicable to the following component categories:
Electronic Modules: A, AS, AM, AX, AY
Electric Motors: EM
9.1 Requirement
Conducted voltage emissions on all component power circuits shall not exceed the requirements listed in Table 9-1.
Figure 9-1: CE 421 Conducted Emissions Requirements
Frequency Range (kHz) Limits (dBuV)*
10 - 20 111
20 - 150
⎟
⎠
⎞
⎜
⎝
⎛
−
20
40111
f
Log
150
60
70
80
90
100
110
120
kHz
dBuV
10010
* f= frequency in kHz
9.2 Test Verification and Test Setup
The test setup is identical to that used for CE 420 except only one Artificial Network is used regardless of how the DUT is
grounded in the vehicle. The setup is shown in Figure 9-1. If the DUT has separate power circuits, separate tests shall be
performed on each circuit. Circuits not being tested shall be connected directly to an automotive battery. This requirement
may be waived if the multiple circuits are used only meet the operating current demands of the DUT (e.g. single power
circuit, but with multiple connector pins). Under these conditions, all power circuits are tied to the artificial network.