Specifications
EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 23 of 121
February 11, 2010
Figure 7-4: Recommended Process for Assessing DUT Emissions to RE310 Level 2 Requirements
(Excludes bands EU1, G1, G8)
Re-measure DUT non-compliant
emissions in accordance with Table
7-4 for Limit A. Measurements shall
be made over entire frequency
band(s) where non-compliance was
noted in Step 1
+
.
Are DUT emissions
below Level 2, Limit A
per Table 7-2? **
Re-measure DUT non-compliant
emissions in accordance with Table
7-4 for Limit B. Measurements shall
be made at all frequencies where
non-compliance was noted in Step 1.
DUT is compliant to
Level 2, Limit A and B
requirements.*
Are all PK emissions
below Level 2, Limit A (PK)
per Table 7-2?
DUT
Non-Compliant
Are DUT emissions
below Level 2, Limit B
per Table 7-2? **
Measure DUT Emissions from 30-1000 and
1447 -1494 MHz using 120 kHz MBW, PK
+
detection and measurement system
requirements listed in Table 7-5.
Step 1
Step 2
N
Y
N
Y
N
Limit A Limit B
Y
DUT
Compliant to
Limit A
DUT
Compliant to
Limit B
Level 1
Evaluation
See Figure 7-3
+ Simultaneous PK and AVG measurements may be made using RF receivers with dual detector capability
* Ambient requirements (6dB) do not apply when using 120 kHz MBW, PK detection to verify Level 2, Limit A
requirements.
** Measurement system and test setup ambient requirements (6dB) apply when using 9/10kHz MBW to verify Level 2, Limit
A requirements.