Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 22 of 121
February 11, 2010
Figure 7-3: Recommended Process for Assessing DUT Emissions per RE 310 Level 1 Requirements
Re-measure DUT emissions at all
non-compliant frequencies in
accordance with Table 7-5 for Limit A
+
.
Are DUT emissions
below Level 1, Limit A
per Table 7-1?
Re-measure DUT emissions at all
non-compliant frequencies in
accordance with Table 7-5 for Limit B.
DUT is compliant to
Level 1, Limit A and B
requirements.
Are all PK emissions
below Level 1, Limit A
per Table 7-1?
DUT
Compliant to
Limit A
DUT
Non-Compliant
Are DUT emissions
below Level 1, Limit B
per Table 7-1?
Level 2
Evaluation
See Figure 7-4
Measure DUT Emissions from 30-1000 and
1447 -1494 MHz using 120 kHz MBW, PK
+
detection and measurement system
requirements listed in Table 7-5.
Step 1
Step 2
Y
NN
N
YY
Limit A Limit B
DUT
Compliant to
Limit B