Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 118 of 121
February 11, 2010
Annex H (Normative): RI 130, RI 150 Test Fixture and Application
The test fixture used for RI 130 and RI 150 is illustrated in Figure H-1. The fixture consists of a wire support fixture
mounted to an aluminum plate. The wire support fixture is constructed from Delrin® 570 NC000. Detailed constructions
plans for this fixture may be found at www.fordemc.com.
Figure H-1: RI 130/150 Test Fixture (Top View)
1000 ± 0.5
1 2
All Dimensions in mm
33 33
Side View
Top View
Without Lid
4
Key
Aluminum Plate Wire Support (Delrin® 570 NC000)
Type N Connector 14 AWG Copper Wire
The fixture contains a single copper wire ("source wire") that is connected to the signal source that generates the disturbances
for RI 130/RI 150. The DUT is tested by placing individual wires in the slot immediately above the source wire (Slot A).
This is illustrated in Figure H-2 below.
Figure H-2: RI 130/150 Test setup ( Default DUT Wire Location )
Slot A
Slot B
Slot C
Source
Wire
DUT
Load
Simulator
Test Harness