Installation Guide
3
Lanikai ShowerSpa Installation Instructions
Congratulations on your purchase of the PULSE Lanikai Rain 
Shower system. There’s no better way to start your day!
Follow these simple steps in the order presented to help avoid 
mistakes. When nished, multiple, soothing showering options 
are at your ngertips.
Assembly and installation of the Lanikai Rain Shower System 
is designed to be quick and easy. If you have any installation 
questions or performance problems call PULSE Customer Service 
toll free at 1-888-785-7320 
(
8:30 am – 5:00 pm pacic time 
Monday – Friday
)
 or email support@pulseshowerspas.com before 
returning this product to the store.
FOR NEW CONSTRUCTION OR COMPLETE REMODEL
• A hot
/
cold Automatic Compensating Shower Valve which 
complies with ASSE 1016-2011/ASME A112.1016-2011/
CSA B125.16-11 is required 
(
NOT INCLUDED
)
• Nipple should extend no more than ½" past nished  
wall surface.
  1.  Determine the length Nipple 
(
D
)
 needed.
a.  Place mark on existing shower arm at wall surface. 
Unscrew shower arm from elbow in wall.
b.  Measure distance from mark on shower arm to end of 
shower arm threads. Add ½" to this measurement, and 
then round to nearest ½".
Example 1: If measurement = 1¼", add ½" = 1¾", 
rounded = 2" NPT nipple—this is the length needed.
Example 2: If measurement = 1
5
/
8", add ½" = 2
1
/
8",  
rounded = 2" NPT nipple—this is the length needed.
IMPORTANT—If existing shower arm is located above the 
tile/berglass wall surface you must add the distance from 
the sheetrock to face of the tile/berglass shower wall to the 
above measurement.
NOTE—If supplied 2" Nipple 
(
D
)
 is not the correct length 
based on above formula, you must obtain the correct size, 
sold separately. Various length NPT brass nipples are readily 
available at most hardware stores.
  2. Apply a generous amount of Teon Tape 
(
N
)
 to both ends of 
the Nipple 
(
D
)
.
  3. Hand tighten Inlet Fitting 
(
C
)
 onto Nipple 
(
D
)
, then Nipple to 
tting in wall. Use adjustable wrench on the Inlet Fitting to 
tighten both connections simultaneously. Continue tightening 
until both connections are secure with no leaks.
 4. Connect Top Tee 
(
B
)
 into Shower Pipe 
(
E
)
 and align with 
Diverter. Make sure Top Tee is fully seated into Shower Pipe 
and secure with Set Screw 
(
K
)
.
 5. Slide Shower Arm 
(
A
)
 into Top Tee 
(
B
)
 and hand-tighten 
Retaining Nut until secure.
 6. Slide Top Escutcheon 
(
F
)
 over Top Tee 
(
B
)
, then slide Bottom 
Escutcheon 
(
F
)
 over Diverter.
  7. Loosen Set Screw 
(
L
)
 on Diverter, slide Lower Mount 
(
G
)
 into 
Diverter and tighten set screw. Do Not Expose Tape!
 8. Push Top Tee 
(
B
)
 over Inlet Fitting 
(
C
)
 until ush against t-
ting. Position Diverter so Shower Pipe 
(
E
)
 is plumb 
(
vertical
)
. 
Mark location of Lower Mount 
(
G
)
 with pencil.
  9. Wall surface must be clean of any residue and completely 
dry. Remove covering of two-face tape and reposition 
Lower Mount 
(
G
)
 to mark so the optional mounting holes are 
horizontal. Apply pressure to mount for 30 seconds by push-
ing rmly against the Diverter. To ensure proper adhesion, 
allow one hour before using your ShowerSpa and keep area 
around the mount as dry as possible for the rst 24 hours. 
Tape will be fully cured after 24 hours.
OPTIONAL—Secure Lower Mount 
(
G
)
 with permanent wall 
anchors. Mark hole locations in Lower Mount. Drill 1¼" deep 
holes using 6mm 
(
1/4"
)
 masonry/tile drill bit. Insert Wall 
Anchors 
(
P
)
 and secure Lower Mount with Screws 
(
O
)
.
CAUTION — LIVE PLUMBING IN WALL
 10.  Position  Shower Pipe 
(
E
)
 parallel to wall by adjusting Diverter  
on Lower Mount 
(
G
)
. Secure Diverter to Lower Mount with 
Set Screw 
(
L
)
.
 11.  Insert  Rubber Washer 
(
M
)
 into both ends of Hose 
(
J
)
. Con-
nect hex-head end to outlet on Diverter and tapered end to 
Hand Shower 
(
I
)
. Place Hand Shower 
(
I
)
 into Holder.
 12.  Inser t  Rubber Washer 
(
M
)
 in Shower Head 
(
H
)
 and tighten 
securely to Shower Arm 
(
A
)
.
Flow Restrictor Information
This unit contains ow restrictors limiting ow to 
2.5GPM/9.5LPM (Model # 1028-CH & 1028-BN) and 
2.0GPM/7.6LPM (Model # 1028-CH-2.0 & 1028-BN-2.0). 
If the ow rate is less than expected, or reduces over time, you 
may have an obstruction at the inlet restrictor.
To check for debris, remove shower unit from wall, exposing the 
Inlet Fitting 
(
C
) (
attached to wall
)
.
Using needle nose pliers, rotate C-clip until one end enters the 
cutout section of the tting, then pull the C-clip out completely.
With needle nose pliers, gently depress the inner yellow ring of 
the restrictor to expose the white spindle. Hold the spindle with 
pliers and pull toward you to remove.
Remove the screen and turn cold water on—SLOWLY.
Run water for 15 seconds to remove debris from water line.
Check screen and restrictor for sediment. Use water and a soft 
nylon brush 
(
if necessary
)
 to remove sediment.
When nished, rst replace the screen, then the restrictor and 
nally the C-clip.
Your Lanikai Showerspa is fully functional with or without 
the restrictors. Depending on your local plumbing codes, the 
restrictors may or may not be necessary.