User Instructions
3 
Fig. 4. The view switch'a. 
1.4. Technical parameters 
 Table 2.   
Ports 
24 x PoE (10/100 Mb/s) (RJ-45) 
 2 x UpLink (10/100/1000 Mb/s) (RJ-45) 
2 x UpLink (10/100/1000 Mb/s) (SFP) 
with connection speed auto-negotiation and MDI/MDIX Auto Cross) 
PoE power supply 
IEEE 802.3af/at (1÷24 ports), 52 V DC / 30 W at each port * 
Protocols, Standards 
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP 
Bandwidth 
14,8 Gbps 
Transmission method 
Store-and-Forward 
Optical indication of 
operation 
Switch power supply 
Link 
PoE Status 
Power supply 
~100-240 V; 50/60 Hz; 3 A 
Operating conditions 
temperature -10 °C ÷ 40 °C,  
relative humidity 5% - 90%, no condensation 
Dimensions 
W=442, H=44, D=224 [+/- 2 mm] 
Additional equipment 
bracket for Rack 19” 
Cable length AC 
1,2 m 
Net/gross weight 
3,0 / 3,5 kg 
Protection class 
EN 60950-1:2007 
I (first) 
Storage temperatur 
-20° C ÷ 60 °C 
Declarations 
CE 