User Instructions

3
Fig. 4. The view switch'a.
1.4. Technical parameters
Table 2.
Ports
24 x PoE (10/100 Mb/s) (RJ-45)
2 x UpLink (10/100/1000 Mb/s) (RJ-45)
2 x UpLink (10/100/1000 Mb/s) (SFP)
with connection speed auto-negotiation and MDI/MDIX Auto Cross)
PoE power supply
IEEE 802.3af/at (1÷24 ports), 52 V DC / 30 W at each port *
Protocols, Standards
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Bandwidth
14,8 Gbps
Transmission method
Store-and-Forward
Optical indication of
operation
Switch power supply
Link
PoE Status
Power supply
~100-240 V; 50/60 Hz; 3 A
Operating conditions
temperature -10 °C ÷ 40 °C,
relative humidity 5% - 90%, no condensation
Dimensions
W=442, H=44, D=224 [+/- 2 mm]
Additional equipment
bracket for Rack 19”
Cable length AC
1,2 m
Net/gross weight
3,0 / 3,5 kg
Protection class
EN 60950-1:2007
I (first)
Storage temperatur
-20° C ÷ 60 °C
Declarations
CE
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 240 W.