 2. Installation. 
2.1. Requirements. 
 The  unit  should  be  mounted  in  confined  spaces,  in  accordance  with  the  2nd  environmental  class,  with  normal 
relative humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow 
of air around the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through 
ventilating holes of the enclosure.  
 The switch load balance should be done before installation. The given value of 30 W per port is the maximum 
value referring to a single output. The total power consumption should not exceed  160 W. The increased demand for 
power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, 
the  power  consumption  increases  rapidly,  which  may  adversely  affect  the  operation  of  the  switch.  As  the  device  is 
designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch,  therefore    an  appropriate  overload 
protection  in  the  power  supply  circuit  should  be  provided.  The  electrical  system  shall  be  made  in  accordance  with 
applicable standards and regulations. 
2.2. Installation procedure. 
1. Connect the 230 V power supply and turn on the device. The connection should be made with the supplied 3-core 
cable with a plug. The place and method of installation of the switch should ensure free air flow around the unit. 
2. Connect the camera wires to the RJ45 connectors (sockets RJ45 from 1 to 16). 
3. Connect the remaining LAN devices to RJ45 connectors or SFP socket (G1/TP and G1/SFP or G2/TP and G2/SFP) 
CAUTION! G1/TP and G1/SFP or G2/TP and G2/SFP connectors can not operate simultaneously! 
4. Check the optical indication of switch operation (see Table 3). 
 Connection schemes 