User Instructions
6 
2.2. Long Range mode 
Switch enables operation in two modes: standard and extended range. When the Long Range switch is in STANDARD 
position (see Fig. 5), PoE ports operate at 100 Mb / s up to 100 meters. After switching to EXTEND position, range is increased 
to 250 meters and speed is reduced to 10 Mb / s. Additionally, VLAN function, which isolates the PoE ports between each other 
(communication takes place between the UpLink ports and individual PoE), is activated. In both modes, the UpLink port speed 
is 100 Mb / s. 
Note: Changing the modes requires a power restart! 
2.3. Installation procedure 
Before installation, cut off the voltage in the 230 V power-supply circuit. 
To switch power off, use an external switch, in which the distance between the contacts of all 
poles in the disconnection state is not less than 3mm. 
2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (230 V) to L-N clips of the PSU.  
The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire 
coat of the power cable shall stick of the terminal - marked with ‘ ‘ symbol on the PSU enclosure. 
Operation of the PSU without the properly made and fully operational shock protection circuit is 
UNACCEPTABLE! It can cause a device failure or an electric shock. 
4. Connect the ground wire to the terminal marked with the   symbol (power supply module connector). Use a 
three-core cable (with a yellow and green   protection wire) to make the connection. Lead the cables to the 
appropriate clips through the insulating bushing of the connection board.  
5. Connect the power (230 V). 
6. Connect the battery (mind the colours):  
 - battery output (+V): BAT+ cable / red, 
- battery output (0V): BAT – cable / GND / black. 
7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network 
(the UPLINK connector). 
8. Check the optical indication of the switch operation. 
9. After installing and checking proper working, the enclosure can be closed.   
 Connection schemes 