Table 5. Mechanical parameters 
Dimensions 
W=397, H=350, D+D1=92+8 [+/- 2mm] 
W1=402, H1=355 [+/- 2mm] 
The dimensions of the 
battery compartment 
370 x 180 x 80mm (WxHxD) max 
Gross/Net weight 
4,8 / 5,1 kg 
Enclosure 
Steel plate, DC01 1,0mm color white RAL 9003 
Closing 
Cheese head screw x 2 (at the front), (lock assembly possible) 
Connectors 
Power supply of the cameras: RJ45 socket 
230 V input: Φ 0,63-2,50 (AWG 22-10), 
Battery output BAT: 6,3F-2,5 
TAMPER output: wires 
Notes 
The enclosure does not touch the assembly surface so that cables can be led. 
Table 6. Operation safety 
Protection class EN 609501:2007 
I (first) 
Protection grade EN 60529: 2002 (U) 
IP20 
Electrical strength of insulation: 
- between input and output circuits of the PSU 
- between input circuit and protection circuit 
- between output circuit and protection circuit 
3000 V AC min. 
1500 V AC min. 
 500 V AC min. 
Insulation resistance: 
- between input circuit and output or protection circuit 
100 MΩ, 500V DC 
Declarations 
CE 
Table 7. Operating parameters 
Operating temperature 
-10ºC...+40ºC 
Storage temperature 
-20ºC...+60ºC 
Relative humidity 
20%...90%, without condensation 
Vibrations during operation 
unacceptable 
Impulse waves during operation 
unacceptable 
Direct insulation 
unacceptable 
Vibrations and impulse waves during transport 
According to PN-83/T-42106 
2.  Installation 
2.1. Requirements 
 The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and 
required for a given country)  for 230 V and  low-voltage installations. It is required to install an installation switch with 
a nominal current of min. 3 A in the power supply circuits outside the power supply unit. 
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity 
(RH=90% max. without condensation) and the temperature from -10°C to +40°C.  
The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of 
the enclosure.  
Before installation, prepare a Switch'a load balance.  
The  given  value  of  30  W  per  port  is  the  maximum  value  referring  to  a  single  output.  The  total  power 
consumption should not exceed 96 W. The increased demand for power is particularly evident in the case of cameras 
with heaters or infrared illuminators  - when launching these features, the power consumption increases rapidly, which 
may  adversely  affect  the  operation  of  the  switch.  As  the  device  is  designed  for  a  continuous  operation  and  is  not 
equipped  with  a  power-switch,  therefore  an  appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply 
circuit. Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate 
fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 