User Instructions

www.pulsar.pl RSUPS108 RACK POWER
2
Example of use.
CONTENTS:
1. Technical description.
1.1. General description
1.2. Block diagram
1.3. Description of components and connectors
1.4. Specifications
2. Installation.
2.1. Requirements
2.2. Installation procedure
3. Indication of the device operation.
3.1. LED indication of operating status
3.2. Optical indication of the switch operation
3.3. Technical output
3.4. Acoustic indication
4. Operation and use.
4.1. Overload or short circuit of the PSU output
4.2. Battery-assisted operation
4.3. Maintenance
Features:
Uninterruptible power supply of 8 IP cameras
(52 V DC)
Switch 10 ports:
8 PoE ports 10/100Mb/s, (1÷8 ports) (data transfer
and power supply)
2 10/100Mb/s ports (UpLink)
30 W for each PoE port, supports devices complaint
with the IEEE802.3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (1K size)
battery charging and maintenance control
excessive discharging (UVP) protection
battery output protection against short circuit and
reverse connection
battery charge current: 0,5 A
(batteries 2x7 Ah / 2x17 Ah)
Approximate backup time: 5h 30min
acoustic indication of failure
LED optical indication: AC, DC, TEMP, LoB,
ALARM
the ALARM technical output of collective failure
– relay type, activated by:
230 V AC power loss
low voltage of the PSU (<23 V)
too high temperature of the PSU (>70°C)
the PSU failure
protections:
SCP short-circuit protection
overvoltage protection
overload protection OLP
forced cooling (fan)
warranty – 2 year from the production date