User Instructions

www.pulsar.pl RSGUPS108R RACK POWER
2
Example of use.
CONTENTS:
1. Technical description.
1.1. General description
1.2. Block diagram
1.3. Description of components and connectors
1.4. Specifications
2. Installation.
2.1. Requirements
2.2. Installation procedure
3. Indication of the device operation.
3.1. LED indication of operating status
3.2. Optical indication of the switch operation
3.3. Technical output
3.4. Acoustic indication
4. Operation and use.
4.1. Overload or short circuit of the PSU output
4.2. Battery-assisted operation
4.3. Maintenance
Features:
DC 52V uninterruptible power supply of 8 IP
cameras
DC 12V uninterruptible power supply of the recorder
Switch 10 ports:
8 PoE ports 10/100/1000Mb/s, (1÷8 ports) (data and
power supply)
2 10/100/1000Mb/s ports (UpLink)
30W for each PoE port, supports devices complaint
with the IEEE802.3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (1K size)
battery charging and maintenance control
excessive discharging (UVP) protection
battery output protection against short circuit and
reverse connection
battery charge current: 1A
(batteries 2x7Ah / 2x17Ah / 2x28Ah)
Approximate backup time: 5h 30min
voltage control at the NVR output
acoustic indication of failure
LED optical indication: AC, DC, TEMP, LoB,
ALARM, NVR
the ALARM technical output of collective failure
relay type, activated by:
230V AC power loss
low voltage of the PSU (<23V)
no voltage at the power supply output of the
recorder
too high temperature of the PSU (>70°C)
the PSU failure
protections:
SCP short-circuit protection
overvoltage protection
overload protection OLP
forced cooling (fan)
warranty 2 year from the production date