RSFUPS108 v.1.0 10-ports switch with buffer power supply for 8 IP cameras, RACK mounted EN Edition: 1 from 22.09.
www.pulsar.pl RACK POWER RSFUPS108 Features: DC 48V uninterruptible power supply of 8 IP cameras Switch 10 ports 8 PoE 10/100Mb/s ports, (1÷8 ports) (data and power supply) 2 ports 10/100/1000Mb/s (ports G1/TP, G2/TP) (UpLink) 2 ports 10/100/1000 Mb/s SFP (G1/SFP, G2/SFP ports) 15,4W for each PoE port, supports devices complaint with the IEEE802.
www.pulsar.pl RSFUPS108 RACK POWER 1. Technical description. 1.1. General description. The RSFUPS108 is a complete solution for power supply and battery backup of 8 IP cameras (48VDC power supply) in RACK 19" standard.
www.pulsar.pl RSFUPS108 BUZZER, micro switch, turning ON / OFF of acoustic indication switch in the top position, indication ON switch in the down position, indication OFF PoE port 1÷8 for cameras IP connection (data + power supply) 2 x UPLINK ports (G1/TP, G2/TP) 2 x UPLINK ports (G1/SFP, G2/SFP) 230V AC INPUT, power socket 230V AC, power cable 1,5m included FMAINS, fuse in the supply circuit 230V AC, T 3,15A/250V Fig. 2. The front power of the power supply unit. Fig. 3. Rear panel of the power supply.
www.pulsar.pl RACK POWER RSFUPS108 Fig.5. The view of the switch. Table 2. (See Fig. 5). Element no. [Fig. 2] Description LINK - yellow LED - indicating the LAN connection status PoE - green LED indicating voltage at the PoE port PWR – green LED indicating the supply voltage of the Switch PoE port 1÷8 for cameras IP connection (data + power supply) 2 x UPLINK ports (G1/TP, G2/TP) 2 x UPLINK ports (G1/SFP, G2/SFP) 1.4. Specifications. - parameters of the switch (tab.3) - electrical parameters (tab.
www.pulsar.pl RACK POWER RSFUPS108 Battery circuit protection SCP and reverse polarity connection Excessive discharge protection UVP Optical indication of operation: Acoustic operation indication: The ALARM technical output of collective failure The FMAINS fuse in the 230V power supply circuit melting fuse U<19V (+/-5%) – disconnect of connection battery LED: AC, DC, TEMP, LoB, ALARM, LINK, PoE Piezoelectric indicator ~75dB/0,3m Relay type: 1A@ 30VDC/50VAC T 3,15A Mechanical parameters (tab. 5).
www.pulsar.pl RSFUPS108 RACK POWER 2.2. Installation procedure. 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the power supply in a RACK 19" cabinet as shown below: - Mount M6 cage nuts - Secure the enclosure with 4xM6 screws 3. Connect the batteries in series/parallel to the + BAT- terminals: - battery output (+): terminal BAT+ - battery output (-): terminal BAT- 4.
www.pulsar.pl RSFUPS108 RACK POWER 3.2.
www.pulsar.pl RSFUPS108 RACK POWER 3.4. Acoustic indication. A collective failure is indicated by the piezoelectric indicator, 1 beep every second. The acoustic indication can be turned off by changing the ON / OFF position of the switch . switch in the up position, indication ON switch in the down position, indication OFF 4. Operation and use. 4.1. Overload or short circuit of the PSU output. In case of overload, the output voltage is automatically shut off, and so is the LED indicator.
www.pulsar.pl RSFUPS108 RACK POWER WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law.