R1612T v.1.0 R 12V/16x1,5A/TOPIC RACK mounted power supply for up to 16 HD cameras. EN** Edition: 2 from 10.04.2017 Supercedes the edition: 1 from 28.01.
www.pulsar.pl RACK POWER R1612T Features: DC 12V/16x0,87A uninterruptible power supply for powering HD cameras (14A max.
www.pulsar.pl RACK POWER R1612T CONTENTS: 1. Technical description. 1.1. General description 1.2. Block diagram 1.3. Description of PSU components and connectors 1.4. Specifications 2. Installation. 2.1. Requirements 2.2. Installation procedure 3. Operating status indication. 3.1. LED indication 3.2. Technical output 3.3. Acoustic indication 4. Operation and use. 4.1. Overload or short circuit of the PSU output 4.2. Maintenance 1. Technical description. 1.1. General description.
www.pulsar.pl RACK POWER R1612T switch in the down position, indication OFF 230V AC INPUT, power socket 230V AC, power cable 1,5m included FMAINS, fuse in the supply circuit 230V AC, T 3,15A/250V F1 ÷ F16, melting fuses in the camera power supply circuits AUX (+), F1,5A Fig. 2. The front power of the power supply unit. Fig.3. The view of the PSU.
www.pulsar.pl RACK POWER R1612T 1.4. Specifications. - electrical parameters (tab.2) - mechanical parameters (tab.3) - operation safety (tab.4) - operating parameters (tab.5) Electrical parameters (tab. 2).
www.pulsar.pl RACK POWER R1612T During normal operation the total current consumption of the receivers cannot exceed I=14A. As the PSU is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-box).
www.pulsar.pl RACK POWER R1612T GREEN LED: on – DC voltage in the AUX1…AUX16 output off – no DC voltage in the AUX1…AUX16 output 3.2. Technical output. The power supply is fitted with the ALARM output of collective failure (relay type). A collective failure can be triggered by the following events: - 230V AC mains power failure - Melting fuse activation F1÷F16 - Failure of the switch mode power supply -Too high temperature of the switch mode power supply (>70°C) Fig. 4.
www.pulsar.pl RACK POWER R1612T WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 E-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.