SDS
_______________________________________________________________________________
Report No.: SHES181200191801
Date: 2019-03-06
Page 9 of 21
This document is issued by the Company subject to its General Conditions of Service, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms
and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be produced except in full, without prior written approval of the
Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Attention: To check the authenticity of testing/inspection report & certificate, please contact us at telephone: (86-755)83071443, or email: CN.Doccheck@sgs.com
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd
201612 t (86-21)61915666 f (86-21)61915678 www.cn.sgs.com
201612 t (86-21)61915666 f (86-21)61915678 e sgs.china@sgs.com
No. 588 West Jindu Rd, Xinqiao Town, Songjiang District, Shanghai CHINA
中
国·上海·松江区金都西路 588 号 邮编:
Open circuit voltage changed not less than 90%, the
requirement relating to voltage is not applicable to
test cells and batteries at full discharged states.
P
No leakage, no venting, no disassembly, no rupture
and no fire.
P
38.3.4.5
Test T.5: External short circuit
P
Test procedure:
The cell or battery to be tested shall be temperature
stabilized so that its external case temperature
reaches 57±2 ºC and then the cell or battery shall be
subjected to a short circuit condition with a total
external resistance of less than 0,1 ohm at 57±4 ºC .
If this assessment is not Feasible, the exposure time
shall be at least 6hours for small cells and small
batteries, and 12 hours for large cells and large
batteries. This short circuit condition is continued for
at least one hour after the cell or battery external
case temperature has returned to 57±4 ºC , The cell
or battery must be observed for a further six hour for
the test to be concluded, or in the large batteries, has
decreased by half of the maximum temperature
increase observed during the test and remains below
the value.
P
Requirement:
Cell’s or batteries’ external temperature not exceed
170 ºC .
P
No disassembly, no rupture and no fire within six
hours.
P
38.3.4.6
Test T.6: Impact / Crush
P
Test procedure 1: Impact
The sample cell or component cell is to be placed on
a flat smooth surface.
The diameter of the cell is 18
mm
P
A 15.8 mm ± 0.1mm diameter, at least 6 cm long, or
the longest dimension of the cell, whichever is
greater, Type 316 stainless steel bar is to be placed
across the centre of the sample.
P
A 9.1 kg ± 0.1 kg mass is to be dropped from a
height of 61 ± 2.5 cm at the intersection of the bar
and sample in a controlled manner using a near
frictionless, vertical sliding track or channel with
minimal drag on the falling mass. The vertical track
or channel used to guide the falling mass shall be
oriented 90 degrees from the horizontal supporting
surface.
P