Report No.: SHES181200191801
Date: 2019-03-06
Page 7 of 21
This document is issued by the Company subject to its General Conditions of Service, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms
and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be produced except in full, without prior written approval of the
Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Attention: To check the authenticity of testing/inspection report & certificate, please contact us at telephone: (86-755)83071443, or email: CN.Doccheck@sgs.com
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd
201612 t (86-21)61915666 f (86-21)61915678 www.cn.sgs.com
201612 t (86-21)61915666 f (86-21)61915678 e sgs.china@sgs.com
No. 588 West Jindu Rd, Xinqiao Town, Songjiang District, Shanghai CHINA
国·上海·松江区金都西路 588 邮编:
3. Test result:
ST/SG/AC.10/11/Rev.6/Section 38.3
Clause
Requirement + Test
Result - Remark
Verdict
38.3.4
Procedure
P
38.3.4.1
Test T.1: Altitude simulation
P
Test procedure:
Test cells and batteries shall be stored at a pressure
of 11,6 kPa or less for at least six hours at ambient
temperature (20±5 ºC ).
P
Requirement:
Cells and batteries Mass loss limit: 0,1%;
P
Open circuit voltage changed not less than 90%, the
requirement relating to voltage is not applicable to
test cells and batteries at full discharged states.
P
No leakage, no venting, no disassembly, no rupture
and no fire.
P
38.3.4.2
Test T.2: Thermal test
P
Test procedure:
Test cells and batteries are to be stored for at least
six hours at a test temperature equal to 75±2 ºC ,
followed by storage for at least six hours at a test
temperature equal to -40±2 ºC . The maximum time
interval between test temperature extremes is 30
minutes. This procedure is to be repeated 10 times,
after which all test cells and batteries are to be
stored for 24 hours at ambient temperature (20±5
ºC ). For large cells and batteries the duration of
exposure to the test temperature extremes should be
at least 12 hours.
P
Requirement:
Cells and batteries Mass loss limit: ≤0,1%
P
Open circuit voltage changed not less than 90%, the
requirement relating to voltage is not applicable to
test cells and batteries at full discharged states.
P
No leakage, no venting, no disassembly, no rupture
and no fire.
P
38.3.4.3
Test T.3: Vibration
P