PSACH01246EKO v.1.0 PSACH 24VAC/6A/1x6A AC power supply for 1 rotating camera, ABS enclosure EN Edition: 1 from 14.04.
www.pulsar.pl PSACH01246EKO Features: ~24 V /6 A power output for powering camera power voltage ~230 V protections: SCP short-circuit protection OLP overload protection OHP overheat protection IP 65 ABS, hermetic enclosure warranty – 2 year from the production date Sample power supply unit for rotating camera supplied with AC voltage. Schematic diagram of a power supply. CONTENTS: 1. Technical description. 1.1 General description 1.2 Block diagram 1.3 Description of PSU components 1.
www.pulsar.pl PSACH01246EKO 1. Technical description. 1.1. General description. The AC/AC PSU intended for supplying devices requiring voltage AC of 24 V and total capacity of 6 A. It features protections: short-circuit (SCP), overload (OLP), transformer overheat (OHP). The PSU is housed in a ABS enclosure. 1.2. Block diagram. Fig.1. Block diagram of the PSU. 1.3. Description of PSU components. Tab.1. Elements of the power supply unit. Element no. Description [Fig.
www.pulsar.pl PSACH01246EKO 1.4 Specifications: - electrical specifications (tab.2) - mechanical specifications (tab.3) - operation safety (tab.4) - operating specifications (tab.5) Electrical specifications (tab. 2). Mains supply Current consumption Power frequency Power of the S PSU Output voltage Output current Short-circuit protection SCP Overload protection OLP Overheat protection OHP F1 fuse F2 fuse Mechanical specifications (tab. 3).
www.pulsar.pl PSACH01246EKO Operating specifications (tab.5). Operating temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct insolation Vibrations and impulse waves during transport -25ºC...+40ºC -25ºC...+60ºC 10%...90% without condensation unacceptable unacceptable unacceptable PN-83/T-42106 2. Installation. 2.
www.pulsar.pl PSACH01246EKO 3.2 Maintenance. Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network. The PSU does not require performing any specific maintenance measures. However, in case of a significant dust level, clean the interior with compressed air. In case of a fuse replacement, use one of the same parameters.