Features:
power output 10A/12÷15V DC
*
wide range of AC input voltage 176÷264V
high efficiency 83%
LED indication
protections:
short-circuit protection SCP
over voltage protection OVP
surge protection
overload protection OLP
warranty – 2 year from the production date
1. Technical description.
1.1. General description.
The power supply unit is intended for 230V AC mains supply to alarm system devices, which require 12V DC voltage
and current efficiency of I=10A. The design enables simple changing of the output voltage, within the range of 12V÷15V DC,
using a potentiometer. The power supply unit is protected against a short circuit, an overload, a surge or over voltage.
1.2. Specifications.
Supply voltage
176 ÷ 264V AC; 50÷60Hz
Current consumption
1,1A@230V AC max.
PSU power
150W max.
Efficiency
83%
Output current t
AMB
<30°C
10A - see chart 1.
Output current t
AMB
=40°C
7A - see chart 1.
Voltage adjustment range
12V ÷ 15V DC
Ripple voltage
100mV p-p max.
Short-circuit protection SCP
electronic (activation requires disconnecting the load or supply for
about 5 s.)
Overload protection OLP
105 ÷ 150% of the PSU power (activation requires disconnecting the
load or supply for about 5 s.)
Surge protection
varistors
Over voltage protection OVP
>16V (activation requires disconnecting the load or supply for about
20 s.)
LED indication
green LED – presence of DC voltage
Operation conditions
2-nd environmental class, temperature: -10
o
C ÷ +40
o
C
relative humidity 20%...90%, without condensation
Dimensions
L=199, W=110, H=50 [+/- 2mm]
Net/gross weight
0,73kg / 0,78kg
Protection class PN-EN 60950-1:2007
I (first) – requires a protective conductor (PE)
Connectors
power-supply:Φ0,63-2,50 (AWG 22-10)
outputs: Φ0,63-2,50 (AWG 22-10)
Dielectric strength of insulation:
- between input (network) circuit and output
circuits of the PSU (I/PO/P)
- between input circuit and PE protection circuit
(I/P-FG)
- between output circuit and PE protection circuit
(O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection
circuit
100 MΩ, 500V DC
Storage temperature
-20ºC...+60ºC
Vibrations and impulse waves during transport
PN-83/T-42106
* In order to extend the life of the power supply, the load current of 7A is recommended.
*