Connecting to LPG Fuel Source
1.Locate the LPG converter on the backside of the generator
2.Attach small end of the Gas Hose to the LPG converter.
3.Connect gas hose to propane fuel source. Do not turn on propane source prior to following the
steps outlined.
Batteries produce explosive gases. Keep sparks, flames and cigarettes away from battery. To
prevent the possibility of creating a spark near the battery, connect charging cables to battery
terminals first, then to the generator. When disconnecting, disconnect the cables at the generator
first.
1. Connect the red cable with the positive terminal of the battery. Ensure the connection is
secured by using the fastener at the battery terminal.
2. Connect the black cable with the negative terminal of the battery. Ensure
the connection is secured by using the fastener at the battery terminal.
Be sure to connect the Electric Start Battery to the Dual fuel Generator set before operation.
Improper connection will cause malfunction.
Do not reverse the polarity of the terminals when charging the battery. Serious damage to the
generator and/or battery may occur. Do not attempt to connect the battery while the generator
engine is running. Disconnect the cables from the battery while the generator is in storage.
3. When using gasoline to start the engine, the battery must be properly connected to the
generator and check the battery voltage is normal.
Electric Start Battery Connection