Replacement Part List
Table Of Contents
- PG5000BiSRCO_manual_1
- PG5000BiSRCO_manual_2
- PG5000BiSRCO_manual_3
- PG5000BiSRCO_manual_4
- PG5000BiSRCO_manual_5
- PG5000BiSRCO_manual_6
- PG5000BiSRCO_manual_7
- PG5000BiSRCO_manual_8
- PG5000BiSRCO_manual_9
- PG5000BiSRCO_manual_10
- PG5000BiSRCO_manual_11
- PG5000BiSRCO_manual_12
- PG5000BiSRCO_manual_13
- PG5000BiSRCO_manual_14
- PG5000BiSRCO_manual_15
- PG5000BiSRCO_manual_16
- PG5000BiSRCO_manual_17
- PG5000BiSRCO_manual_18
- PG5000BiSRCO_manual_19
- PG5000BiSRCO_manual_20
- PG5000BiSRCO_manual_22
6
Control Panel
5
1
2
3
6
7
11
8
9
10
13
14
15
1617
18
19
4
12
1. 120 Volt AC, 20 Amp Duplex NEMA 5-20R Receptacle: The
receptacle can supply a maximum of 20 Amps.
2. Ground Terminal: The ground terminal is used to externally
ground the generator.
3. Parallel Connectors: A compatible Pulsar Inverter Generator
can be connected for additional power output.
4. LED Switch: Light the panel up when the LED Switch is turned
on.
5. USB Ports: USB Type A 5V/3.6A, 9V/2.5A,12V/2A and USB
Type C.
6. Low Oil LED: Indicates low oil level. When the oil level in the
crankcase falls below the safe operating limit, the low oil level
indicator will illuminate and the generator will automatically shut
off the engine.
7. Overload LED: Indicates that the generator is overloaded.
8. Output Ready LED: Illuminates when the generator
is operating normally. Indicates the generator is producing power.
9. Fuel Selector Switch: Used to select gas or propane
10. LPG/Propane Inlet: Connect the LPG/propane hose (included)
to this inlet.
11. Battery Charging Port: Used to charge the battery with the
included battery charger.
12. Start Indicator:Indicates the generator is running.
13. Eco Mode: Eco mode minimizes fuel consumption and noise
by adjusting the engine RPM to the minimum required for the
current load.
14. Push Button Start/Stop: Push once to automatically start the
engine. Push again to stop the engine.
15. Battery Switch: Turns battery ON and OFF. Must be ON before
electric start or remote start.
16. 20 Amp AC Circuit Breaker: Circuit breaker limits the current
that can be delivered through the NEMA 5-20R receptacle
to 20 Amps.
17. 30 Amp AC Circuit Breaker: This circuit breaker limits
the current that can be delivered through the NEMA TT-30
receptacle to 30 Amps.
18. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle: This
receptacle can supply a maximum of 30 Amps.
19. CO Sentry Indicator Lights: The CO Sentry monitors the
accumulation of poisonous carbon monoxide gas. If increasing
levels of CO gas are detected, the CO Sentry automatically shuts
down the engine.