Replacement Part List

14
Operation
2. If the OVERLOAD light turns on and the generator stops
producing power, it has been overloaded.
3. Turn off and disconnect all electrical devices and stop the
engine. Compare device requirements to generator rating and
reduce the total wattage of connected devices if necessary.
Move anything that may be limiting generator ventilation away.
4. Check if any circuit breakers have tripped and make sure that
ALL circuit breakers are reset before starting the generator again.
5. Restart the engine and reconnect devices while being careful
to not overload the generator.
Low Oil Indicator
1. If the engine oil level is too low, the LOW OIL light turns on
270ml and the engine will automatically shut off.
2. The engine cannot be restarted until the proper amount of oil
has been added. Add the appropriate type of oil until the oil level
is at the proper level. SAE 10w-30 oil is recommended for
general use.
Low Idle Switch
1. Turn the low idle switch ON to limit noise and fuel consumption
for lighter generator loads.
2. Switch low idle OFF to operate engine at full speed when:
Starting the generator
A heavy load is applied
Stop The Engine
1. Turn off and unplug all connected electrical loads. Never start
or stop the generator with electrical devices plugged in or
turned on.
2. Push-Button Stop: Press the push-button once to stop the
engine.
Remote Key Stop: Press STOP on the remote start key fob for
0.5 second to stop the engine.
Do not run the engine with too little oil. Engine will shut off if
engine oil level is too low.
NOTICE
ON
OFF
Key Fob
Activation Light
OFF Button
ON Button