User Guide

ENGLISH
Tighten the screw (18) using a 4mm Allen key. The clamping force should be
1.5-2 Nm (use a torque screwdriver) to ensure the lever is correctly tightened
(19), while the Ring Adapter with the thermal imaging module should not
move relative to the body of the optical device (13). If necessary, tighten or
loosen the screw (18) to operate the lever (19) in the best way possible.
Tighten the locking screw (17) as far as it will go.
Turn on the thermal imaging module by briey pressing the ON button (9).
Align the image centre on the Krypton XG50 display with the image centre of
the daylight optical device by carefully tilting the thermal imaging module.
Align the top and bottom display boundaries of the Krypton XG50 parallel to
the horizontal line of the daylight optical device’s reticle.
Having reached the best possible position of the thermal imaging module,
tighten the two screws (16) until stop. The clamping force should be
6.5-7.5 N·m (use a torque screwdriver to check).
Open
Close
16
17
13
14
18
15
19
5