HPSB 2512B v.1.0 HPSB 13,8V/2A/7Ah Buffer, switch mode power supply unit. EN* Edition: 7 from 24.10.2016 Supercedes the edition: 6 from 11.08.
www.pulsar.
www.pulsar.pl HPSB2512B 1.2 Block diagram (fig.1). Fig.1. The block diagram of the PSU. 1.3 Description of PSU components and connectors ( tab.1, tab.2, fig.2). Part no. Description [Fig. 2] [1] PSU module [2] connectors (see: tab.2) [3] green LED indicates AC power [4] P1 potentiometer, output voltage adjustment [5] BAT+/GND: battery outputs + BAT=red, - GND=black [6] TAMPER, contact, sabotage protection (NC) [7] Additional connector for LED indication Tab.1. The components of the PSU. Part [Fig.
www.pulsar.pl HPSB2512B Fig.2. The view of the PSU.
www.pulsar.pl HPSB2512B GREEN POWER 1.4 Specifications: - electrical parameters (tab.3) - mechanical parameters (tab.4) - operation safety (tab.5) - operating parameters (tab.6) Electrical parameters (tab.
www.pulsar.pl GREEN POWER HPSB2512B Operation safety (tab.5) Protection class PN-EN 60950-1:2007 Protection grade PN-EN 60529: 2002 (U) Electrical strength of insulation: - between input and output circuits of the PSU (I/P-O/P) - between input circuit and PE protection circuit (I/P-FG) - between output circuit and PE protection circuit (O/P-FG) Insulation resistance: - between input circuit and output or protection circuit Operating parameters (tab.
www.pulsar.pl HPSB2512B GREEN POWER 2.2 Installation procedure. 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the PSU in a selected location and connect the wires. 3. Connect the power cables (~230Vac) to L-N clips of the PSU. Connect the ground wire to the clip marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection wire) to make the connection.
www.pulsar.pl HPSB2512B GREEN POWER WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. CAUTION! The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must not be thrown but recycled according to the applicable law. Pulsar sp. j.