Data Sheet

SPECIFICATION
88%
89%
90% 90%
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD Note.4
OVER VOLTAGE
500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load
30ms/230VAC 12ms/115VAC at full load
85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )
47 ~ 63Hz
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH non-condensing
0.03%/ (0 ~ 50) RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
856.5K hrs min. MIL-HDBK-217F (25)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 6)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 a EN50178,pproved; Design refer to TUV EN60950-1
℃
EN55024, EN61000-6-2, EN61204-3
EMC IMMUNITY
EMC EMISSION
Parameter
Conducted
Radiated
Harmonic Current (Note 5)
Voltage Flicker
Standard
EN55032(CISPR32)
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Radiated Susceptibility
EFT/Burest
Surge
Standard
EN61000-4-2
Test Level /Note
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Level 4,2KV/L-N, criteria A
Conducted
Magnetic Field
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
Voltage Dips and interruptions
Level 3, criteria A
Level 3, criteria A
Level 3, criteria A
Level 4, criteria A
EN55032(CISPR32)
OPERATING ALTITUDE
2000 meters
HDR-100-12
HDR-100-15
HDR-100-24
12V
15V
24V
7.1A
6.13A
3.83A
0 ~ 7.1A
0 ~ 6.13A
0 ~ 3.83A
85.2W
92W
92W
120mVp-p
120mVp-p
150mVp-p
1.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
HDR-100-48
48V
1.92A
0 ~1.92A
92.2W
240mVp-p
1.0%
1.0%
1.0%
3A/115VAC 1.6A/230VAC
COLD START 35A/115VAC 70A/230VAC
HDR-100 : 102 ~ 110% rated output power;HDR-100-xxN : 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V
56.5 ~ 64.8V
70*90*54.5mm (W*H*D)
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
File Name:HDR-100-SPEC 2017-05-03
0.27Kg; 48pcs/14Kg/1.10CUFT
15 ~ 17V
24 ~ 25.5V
12 ~ 13V
48 ~ 48.7V
Non LPS
Pass LPS
RANGE
VOLTAGE ADJ.
13.5 ~ 18V
21.6 ~ 29V
12~ 13.8V
43.2 ~ 55.2V
85 ~ 100W Ultra Slim Step Shape DIN Rail
HDR-100-12N
7.5A
0 ~ 7.5A
90W
HDR-100-15N
6.5A
0 ~ 6.5A
97.5W
HDR-100-24N
4.2A
0 ~ 4.2A
100.8W
HDR-100-48N
2.1A
0 ~ 2.1A
100.8W
μμ
H D R - 1 0 0 s e r i e s