Model: G465GN Generator OPERATOR’S MANUAL www.pulsar-products.
TABLE OF CONTENTS Introduction..............................................................................................................................................................................3 Product Specifications..................................................................................................................................................3 Parts Ordering / Customer Service.......................................................................................................
INTRODUCTION Thank you for purchasing this superior quality portable generator from Pulsar Products Inc. When operating and maintaining this product as instructed in this manual, your generator will give you many years of reliable service. Product Specifications: This generator is an engine-driven, revolving field, alternating current (AC) portable generator.
SAFETY RULES Safety Symbols WARNING! Indicates a potentially hazardous situation which could result in serious injury or death if not avoided. CAUTION! Indicates a potentially hazardous situation which could result in damage to equipment or property. Toxic Fumes Risk of electric shock Risk of fire Risk of explosion Hot surface Lifting hazard Safety Instructions The manufacturer cannot anticipate every possible hazardous circumstance that the user may encounter.
SAFETY RULES WARNING! Never exceed generator’s wattage / amperage capacity. This could damage the generator and / or connected electrical devices. • Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator. • • Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices.
SAFETY RULES This generator produces a very high voltage which could result in burns or electrocution causing serious injury or death. Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet. Always keep the generator dry. Never operate generator in rain or under wet conditions. Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel work.
FEATURES O P I - Grounding Connection J - Hour Meter K - Oil Dipstik L - Recoil Starter Grip M - Fuel Valve (ON/OFF) N - Choke Level O - ON/OFF Start Switch P -Oil Alert A - Fuel Tank Vapor Vent B - Fuel Fill Cap C - Fuel Tank D - 2-120V Receptacles E - Circuit Protector F - 120V/240V 30Amp Twist Lock G - Voltage Selector Switch H - 120V 30Amp RV 7
ASSEMBLY Unpacking 1. Place box on a level surface. 2. Remove all items from box except the generator. Make sure all items listed on the packing list are included and not damaged. 3. Cut down the sides of the box being careful to avoid hitting the generator. Packing List Check all loose parts to the following list. Contact your dealer if any loose parts are not included.
ASSEMBLY Adding Fuel (See fig 2) • • • Set generator on a clean and level surface in an area that is well ventilated. Remove fuel cap. Insert a funnel into the fuel tank and carefully pour gasoline into the tank until fuel level reaches 1 ½ inches below the top of the neck. Be careful not to overfill the tank to provide space for fuel expansion. CAUTION! You must add oil before first operating this generator. Always check oil level before each operation. DO NOT USE E15 OR E85 FUEL IN THIS UNIT.
OPERATION Grounding the Generator (See fig 3) The ground terminal located on the front panel of the generator must always be used to connect generator to a driven ground rod. Connect the ground terminal to the driven ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects to the terminal between the lock washer and nut. Tighten the nut securely to ensure proper connection.
OPERATION CHOKE RUN CHOKE LEVER Fig 4 Fig 5 WAIT 5sec CHOKE 1 RUN CHOKE LEVER ON OFF 2 Fig 7 Fig 6 Recoil Start How to Stop Engine (See fig 8-10) • • All loads MUST be disconnected from the generator. Never start or stop the engine with electrical devices plugged in to the receptacles. Turn the fuel valve to the “OFF” position. • Turn the engine ON/OFF switch to the “OFF” position.
OPERATION Receptacles and Extension Cords Only use high quality, well-insulated, grounded extension cords in good condition with generator receptacles. Extension cords should have a minimum rating of 125 Volts AC, 20 Amps and should be kept as short as possible to minimize voltage drop. Follow each load manufacturer’s power rating recommendation when selecting receptacle and extension cord. • • • Two 120 Volt AC, 20 Amp receptacles.
OPERATION Ground Fault Circuit Interrupter Receptacles are protected by a Ground Fault Circuit Interrupter (GFCI) to prevent users from electrocution caused by moisture or from faulty electrical devices attached to generator. (GFCI) receptacles do not protect against short circuits, overloads, or shocks. To test the (GFCI) receptacles depress the TEST button and make sure the RESET button pops out. To restore power to the receptacle, depress the RESET button.
OPERATION Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 Hz frequency variation from the generator name plate ratings. To reduce the risk of damage, always have an additional load plugged into the generator if solid state equipment (such as television set) is used.
OPERATION Power Management • • • Start engine without anything connected to generator. When engine has stabilized, plug in and turn on first load. It is strongly recommended to plug in devices with the largest output first and the smallest output last to help prevent overloading the generator. Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.
MAINTENANCE Regular maintenance will extend the life of this generator and improve its performance. The warranty does not cover items that result from operator negligence, misuse, or abuse. To receive full value from the warranty, operator must maintain the generator as instructed in this manual, including proper storage. Before inspecting or servicing this machine, make sure the engine is off and no parts are WARNING! moving. Disconnect the spark plug wire and move it away from the spark plug.
MAINTENANCE Changing Oil (See Fig 11) Oil drainage plug Fig 11 104 86 68 50 * 32 14 -4 40 * * 30 20 10 0 5W-30 Do not use special additives. Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected. Synthetic 5W-30 • • C F Oil Recommendations 10W-30 • Run the Generator until the Engine is warm. Place generator on a level surface. Remove the crankcase dipstick.
MAINTENANCE Cooling System Cooling system should only be serviced by an authorized dealer. Carburetor Adjustment The carburetor is low emission and is equipped with a non-adjustable idle mixture valve. If adjustment is needed contact an authorized dealer. Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system, drain the fuel from the tank and carburetor before storing the unit for long periods of time. This will help prevent starting problems in the future.
TROUBLESHOOTING Problem Engine is running, but AC output is not available Cause 1. Open circuit breaker 2. Poor connection 3. Defective cord set 4. Connected device is faulty 5. Fault in generator Engine runs well without load but bogs 1. Short circuit in connected device down when loads are connected 2. Generator is overloaded 3. Clogged fuel filter 4. Engine speed is too slow 5. Short circuit in generator Engine will not start, shuts down during 1.
DIAGRAMS 20
WARRANTY Pulsar Products Inc. Limited 1 Year Warranty: From the date of original purchase, Pulsar Products Inc. warrants to the original purchaser that each portable generator sold, shall be free from defect in material and workmanship for the items and time period set forth below. Pulsar Products Inc., at its discretion, agrees to repair or replace any defective part that upon examination, inspection, and testing by a Pulsar Products Inc.
WARRANTY What this Warranty Does Not Cover: • Normal wear: This warranty excludes normal wear items such as filters, spark plugs, gaskets, O-rings, adapter cord sets, wheels, and starting batteries. • Maintenance: This warranty does not apply to tune-ups or routine maintenance and does not cover any adjustments or repairs not performed by an authorized repair facility.