User Instructions

2
Connection schemes:
2. Installation.
2.1. Requirements.
The extender should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a
given country) for low-voltage installations. The device shall be mounted in confined spaces (in accordance with the 2nd environmental
class) with normal air humidity (RH=90% max. without condensation) and the temperature from -10°C to +40°C
The device is designed for a 10Mbit/s or 100Mbit/s Ethernet network (the so-called Fast Ethernet). However, it cannot be
used in 1Gbit/s networks (the so-called Gigabit Ethernet). The minimum category cable recommended to connect the extender and
the network device is UTP Cat. 5 cable.
2.2. Installation procedure.
Connect the network cables (Ethernet) to the RJ45 connectors marked PoE IN and PoE OUT. Connect the RJ45 cable from
the Ethernet switch to the PoE IN jack. When using a switch non compliant with the PoE standard, connect an external power source to
the DC IN jack. Then, use the jumper to choose the power source. Connect devices, such as IP cameras, to the PoE OUT 1/2 outputs
e.g. IP cameras.
3. Maintenance.
Any and all maintenance operations may be performed following the disconnection of the power supply from the power
network. The power supply does not require any specific maintenance procedures, however, in the case of significant level of dust, it
should be cleaned with compressed air.
WEEE MARK
According to the EU WEE Directive It is required not to dispose of electric or electronic
waste as unsorted municipal waste and to collect such WEEE separately.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl