1.3.  Technical parameters: 
- Electrical parameters (Table 3) 
- Mechanical parameters (Table 4) 
 Table 3. 
The input voltage range (power supply) 
9,5V÷16V DC 
The output voltage range 
5V÷15V,  factory setting: 12V 
P module power 
36W max. (see fig.3) 
Energy efficiency 
82%÷ 88% 
Ripple voltage 
60mV p-p max 
Output current 
3,0A max. (See fig.3) 
Current consumption by module systems 
15 mA max. 
Short-circuit protection SCP 
electronic, automatic recovery 
Overload protection OLP 
110-150% of the module’s power, manual restart (the failure 
requires disconnection of the DC output circuit) 
Technical outputs 
- PSU output indicating failure – overload or short-
circuit in the AUX output 
- OC type, 50mA max. Failure status: hi-Z state (high 
impedance), normal status: L level (0V) 
Optical indication 
- IN LED indicating DC power status 
- AUX LED indicating DC supply status at the output 
- PSU LED indicating failure - overload or short-
circuit in the AUX output 
- red, normal status: is lit continuously 
- green, normal status: is lit continuously 
- red, normal status: does not lit, failure: is lit continuously 
Operating conditions 
II environmental class, -10°C ÷40°C, ensure air flow around 
the unit for convection cooling 
Declarations, Warranties 
CE, 2 years from the production date 
 Table 4. 
Dimensions 
L=140, W=43, H=45 [+/- 2mm] 
Mounting 
tape or mounting screw x 2 
Terminals 
Ф0,41÷1,63 (AWG 26-14) 
Net/gross weight 
0,13/0,17 kg 
2. Installation. 
2.1. Requirements. 
 The DC/DC converter is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required 
for a given country) for step down installations. The module should be mounted in confined spaces with normal relative humidity 
(RH=90% maximum, no condensation) and temperature range from -10°C up to +40°C. The module should operate in vertical position 
in order to provide free and convectional air flow.  
 Proper operation of the module requires adequate current capacity of the power source; the power supply capacity should be 
calculated using the formula below: 
PIN = 1,25 x PAUX 
(PIN = 1,25 x IAUX x UAUX) 
Example: 
  The converter will supply the receivers with a capacity of P
AUX 
= 36W drawing a total current of I
AUX 
= 3A at the voltage 
U
AUX 
= 12V. The minimum power supply capacity must therefore amount to: P
IN 
= 1,25 x 3A x 12V = 45W. 
 The device should be mounted in a metal enclosure (cabinet). The rules for power supply, enclosures and shielding - according to 
application - must be observed in order to meet the requirements of LVD and EMC directives.  
The  module's  load  balance  should  be 
done  prior  to  installation.  During  normal 
operation, the total current of the receivers should 
not exceed I=3A while the power drawn from the 
module should not exceed Pmax=36W, as shown 
in the Fig. 3. 
Fig.3. The maximum output current 
depending on the output voltage. 