User Instructions

6
8. Technical parameters
Battery compartment
7Ah / 12V
Transformer compartment
TRP: 20÷80VA, TRZ: 20÷80VA
Tamper protection:
- Pulling out the enclosure from
RACK profiles
- Enclosure opening
- Patch Panel opening
the C/NO terminals (C/NC closed housing),
1A@30VDC/3A@250VAC
the C/NO terminals (C/NC closed housing), 0,5A@30VDC/50VAC
the C/NO terminals (C/NC closed housing), 0,5A@30VDC/50VAC
PCB Signal Boards
A/B Board 8 signal lines - 30VDC/1,5A 1 pair
C/D Board 8 signal lines - 30VDC/1,5A 1 pair
E/F Board 8 signal lines - 30VDC/1,5A 1 pair
PCB Power Board
230VAC/max.5A
Mounting dimensions:
W=19", H=2U
Enclosure dimensions
W=395, H=89, D=400 mm
Net/gross weight:
8,30 / 9,50 [kg]
Finish:
- steel plate 1 / 1,5mm, color black (RAL 9004)
Application:
Indoor
Notes:
- The enclosure is mounted using the ARAS800/1000 rails
depending on the depth of the RACK 19" cabinet + 2xM6 screws
butt mounted to RACK profiles
- Patch Panel mounting 4xM6 butt mounted to RACK profiles +
2xM6 to ARAS800/1000 rails
- The set includes:
protective tube MM020 ø21/ø29 0,5m
protective tube MM064 ø6/ø10 – 0,5m
cable tie (black) 100x2,5 - 10 pieces
cable tie (black) 190x4,8 - 4 pieces
Six M6 screws+ cage nuts + plastic washer
2 M6 screws + plastic washer
Available accessories:
- MM020 - protective tube ø21/ø29 – signal wires
- MM064 - protective tube ø6/ø10 – for power cord
- ARAW45 - fan
- AWZ618 - 230VAC board with the F3,15A melting fuse
- transformers of the TRP/TRZ series: 20÷80VA
Declarations, warranty
CE, 2 years from the production date
MANUFACTURER
Pulsar
Siedlec 150, 32-744 Łapczyca
Phone (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl
WARRANTY
Pulsar (the manufacturer) grants a two-year quality warranty for the equipment, starting from the
production date