Data Sheet
SPECIFICATIONS
Battery compartment: 7Ah / 12V
Transformer compartment: TRP: 20÷80VA, TRZ: 20÷80VA
Tamper protection:
- Pulling out the enclosure from RACK profiles
- Enclosure opening - the C/NO terminals (C/NC closed housing), 0,5A@30VDC/50VAC
- Patch Panel opening - the C/NO terminals (C/NC closed housing), 0,5A@30VDC/50VAC
Enclosure dimensions: W=395, H=89, D=400 mm
Net/gross weight: 8,30 / 9,50 [kg]
Mounting dimensions: W=19", H=2U
PCB Power Board: 230VAC/max. 5A
PCB Signal Boards: - A/B Board – 8 signal lines - 30VDC/1,5A – 1 pair
- C/D Board – 8 signal lines - 30VDC/1,5A – 1 pair
- E/F Board – 8 signal lines - 30VDC/1,5A – 1 pair
- the C/NO terminals (C/NC closed housing), 1A@30VDC/3A@250VAC
Application: Indoor
RACK 19" enclosures
Pulsar
®
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50, www.pulsar.pl, e-mail:sales@pulsar.pl
Finish: - steel plate 1 / 1,5mm, color black (RAL 9004)
Notes: - The enclosure is mounted using the ARAS800/1000 rails
of the RACK 19" cabinet + 2xM6 screws butt mounted to RACK profiles
- Patch Panel mounting – 4xM6 butt mounted to RACK profiles + 2xM6
to ARAS800/1000 rails
- The set includes:
• protective tube MM020 ø21/ø29 – 0,5m
• protective tube MM064 ø6/ø10 – 0,5m
• cable tie (black) 100x2,5 - 10 pieces
• cable tie (black) 190x4,8 - 4 pieces
• Six M6 screws+ cage nuts + plastic washer
• 2 M6 screws + plastic washer
depending on the depth
Available accessories: - MM020 - protective tube ø21/ø29 – signal wires
- MM064 - protective tube ø6/ø10 – for power cord
- ARAW45 - fan
- AWZ618 - 230VAC board with the F3,15A melting fuse
- transformers of the TRP/TRZ series: 20÷80VA
Declarations, warranty: CE, 2 years from the production date