6. Specifications
Input Power
115 Volt/ 60Hz, 115 Volt/ 50Hz, 220 Volt/ 60 Hz, or 220 Volt/
50Hz
Stroke Length Control
0 – 100% control range
Resolution – 0.0625% increments
Stroke Adjustment response
Approximately 1% per second
Analog Input
Operating Range
0 to 25.5mA (4-20 mA factory default)
Input Impedance
160 ohms
Minimum Span
2.0 mA
Isolation
500V from all other inputs, outputs and ground, optical ly
isolated
Conditioning
8 second running average.
Split Ranging and Reverse Acting acce ssible via calibration.
Analog Output
Operating Range
0 to 25.5mA (4-20 mA factory default)
Maximum Load
700 ohms
Minimum Span
2.0 mA
Conditioning
None. Output represents current stroke position.
Split Ranging and Reverse Acting acce ssible via calibration.
Isolation
500V from all other inputs, outputs and ground, optical ly
isolated.
Status Input
Motor On/Off
Optically isolated dry contact input. Open contact in dicates
motor is off. Controller will then suspend all stroke control
action. Motor starter should provide a contact for connection
here.
Environmental
Rated Ambient Temperature
-20C to 40C (-4F to 104F)
Storage Ambient Temperature
-25C to 60C (-13F to 140F)
Enclosure
NEMA7, IP66, NEMA4X
Approvals
UL/ULC - NEMA 7
UL 1203: Class I, Division I, Groups C & D Hazardous
Locations
Cenelec–IP66
Cenelec – XP, Class I, Zone I, Group IIB, (EEx d IIb T6)
(DEMKO)
CE – LVD, EMC